4.4 Article

Evaluation of Partial Digestion as a Strategy for Elemental Analysis of Inorganic Samples by Inductively Coupled Plasma-Optical Emission Spectrometry (ICP OES)-A Proof of Concept Study

期刊

ANALYTICAL LETTERS
卷 55, 期 3, 页码 505-515

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/00032719.2021.1945616

关键词

Inductively coupled plasma-optical emission spectrometry (ICP OES); inorganic samples; microwave-assisted digestion; partial digestion; sample preparation

资金

  1. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq) [147727/2018-9, 141634/2017-0, 305201/2018-2, 428558/2018-6]
  2. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES/PNPD-Graduate Program in Chemistry, Federal University of Sao Carlos)
  3. Instituto Nacional de Ciencias e Tecnologias Analiticas Avancadas-CNPq [573894/2008-6]
  4. FAPESP [2014/50951-4]

向作者/读者索取更多资源

This study explores the use of microwave-assisted sample preparation combined with inductively coupled plasma-optical emission spectrometry to determine the content of various inorganic elements. It was found that using diluted nitric acid solutions instead of HF for quantitative analysis of zinc oxide, kaolin, zinc residue, and zinc sulfide is feasible, but tailored procedures need to be considered.
This study discusses the application of microwave-assisted sample preparation for inorganic samples using concentrated or diluted HNO3 solutions followed by determination of Al, Ca, Cu, Cr, Fe, K, Mg, Mn, Na, Ni, P, Pb, S, Si, and Zn using inductively coupled plasma-optical emission spectrometry (ICP OES). Aiming the total digestion (reference procedure), samples were decomposed in a heating block using a mixture of 2 mL of 40% v v(-1) HF and 5 mL of 14 mol L-1 HNO3. Four digestion mixtures composed by (1) 14, (2) 7.0, (3) 4.0, and (4) 2.0 mol L-1 HNO3 plus 3 mL of concentrated H2O2 were evaluated as alternatives for microwave-assisted digestion of six inorganic samples (partial digestion). Considering all evaluated procedures, quantitative recoveries were obtained applying reference and partial digestion procedures. Therefore, the use of HNO3 dilute solutions as an alternative for HF is a feasible procedure for quantitative analysis of zinc oxide, kaolin, zinc residue, and zinc sulfide. However, tailored procedures must be taken into consideration, since quantitative determination depends on digestion mixture, sample matrix, and analytes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据