4.8 Article

Development and Application of Liquid Chromatographic Retention Time Indices in HRMS-Based Suspect and Nontarget Screening

期刊

ANALYTICAL CHEMISTRY
卷 93, 期 33, 页码 11601-11611

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.1c02348

关键词

-

资金

  1. NORMAN Association
  2. Hellenic Foundation for Research and Innovation (HFRI)
  3. General Secretariat for Research and Technology (GSRT) under the HFRI Ph.D. Fellowship grant [14484]
  4. Luxembourg National Research Fund (FNR) [A18/BM/12341006]

向作者/读者索取更多资源

This study proposed a unified retention time index (RTI) approach for liquid chromatography, aiming to achieve comparable retention times among different laboratories. By calibrating the elution pattern with two sets of calibration compounds, the RTI range was set between 1 and 1000, which was considered the most appropriate RTI system after rigorous evaluation.
There is an increasing need for comparable and harmonized retention times (t(R) ) in liquid chromatography (LC) among different laboratories, to provide supplementary evidence for the identity of compounds in high-resolution mass spectrometry (HRMS)-based suspect and nontarget screening investigations. In this study, a rigorously tested, flexible, and less system-dependent unified retention time index (RTI) approach for LC is presented, based on the calibration of the elution pattern. Two sets of 18 calibrants were selected for each of ESI+ and ESI-based on the maximum overlap with the retention times and chemical similarity indices from a total set of 2123 compounds. The resulting calibration set, with RTI set to range between 1 and 1000, was proposed as the most appropriate RTI system after rigorous evaluation, coordinated by the NORMAN network. The validation of the proposed RTI system was done externally on different instrumentation and LC conditions. The RTI can also be used to check the reproducibility and quality of LC conditions. Two quantitative structure-retention relationship (QSRR)-based models were built based on the developed RTI systems, which assist in the removal of false-positive annotations. The applicability domains of the QSRR models allowed completing the identification process with higher confidence for substances within the domain, while indicating those substances for which results should be treated with caution. The proposed RTI system was used to improve confidence in suspect and nontarget screening and increase the comparability between laboratories as demonstrated for two examples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据