4.7 Article

One-step time-resolved fluorescence microsphere immunochromatographic test strip for quantitative and simultaneous detection of DON and ZEN

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 413, 期 26, 页码 6489-6502

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-021-03612-0

关键词

Deoxynivalenol; Zearalenone; Time-resolved fluorescence microspheres; Immunochromatographic test strip; Simultaneous detection

资金

  1. National Key Research and Development Program of China [2018YFC1604206]
  2. National Natural Science Foundation of China [31772069]
  3. Natural Science Foundation of Jiangsu Province [BK20190584]
  4. fellowship China Post doctoral Science Foundation [2020M671343]
  5. Agricultural Science and Technology Innovation Program [CAAS-ASTIP-2020-IFST-03]
  6. Collaborative Innovation Center of Food Safety and Quality Control
  7. national first-class discipline program of Food Science and Technology [JUFSTR20180303]

向作者/读者索取更多资源

A one-step time-resolved single-channel immunochromatographic test strip and a dual-channel test strip were developed for sensitive detection of DON and ZEN, with good recovery results in real samples. The test strips show potential for broad applications in agricultural products.
Deoxynivalenol (DON) and zearalenone (ZEN) are mycotoxins that contaminate a wide range of grains and crops. In this study, a one-step time-resolved single-channel immunochromatographic test strip based on europium ion polystyrene fluorescence microspheres was first developed for sensitive and quantitative detection of DON and ZEN. The concentration of the artificial antigen and the mass ratio of the monoclonal antibody to fluorescent microspheres for conjugation were optimized to simplify the sample addition process during immunochromatographic assay and improve the on-site detection efficiency. The limits of detection (LOD) of the single-channel immunochromatographic test strip for DON and ZEN detection were 0.17 and 0.54 mu g/L, respectively. Meanwhile, the dual-channel immunochromatographic test strip was designed to simultaneously detect DON and ZEN, with LODs of 0.24 and 0.69 mu g/L achieved for DON and ZEN, respectively. The developed test strips also yielded recovery results consistent with that obtained by LC-MS/MS for DON and ZEN detection in real samples of wheat and corn flour, confirming the practicability and reliability of the test strip. The developed immunochromatographic test strips realize quick and sensitive detection of DON and ZEN, exhibiting potential for broad applications in the point-of-care testing platform of multiple mycotoxins in agricultural products.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据