4.7 Article

Ultrasensitive electrochemical molecularly imprinted sensor based on AuE/Ag-MOF@MC for determination of hemoglobin using response surface methodology

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 413, 期 19, 页码 4895-4906

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-021-03453-x

关键词

Hemoglobin (Hb); Molecularly imprinted Ag metal-organic framework mesoporous carbon polymers (Ag-MOF@MC-MIPs); Differential pulse voltammetry (DPV)

资金

  1. Science Foundation of the Isfahan University of Technology, Center of Excellence in Sensors and Green Chemistry

向作者/读者索取更多资源

A highly sensitive electrochemical sensor was developed for determining hemoglobin levels, utilizing an AuE modified with Ag-MOF@MC and MIPs to create a sensing system. The system showed a wide linear dynamic range and low detection limit for Hb concentration measurement, with good stability and reproducibility. The sensor was successfully applied to real blood samples, demonstrating acceptable recovery and reliability in Hb determination.
Considering the importance of determining the levels of hemoglobin (Hb) as a vital protein in red blood cells, in this work a highly sensitive electrochemical sensor was developed based on a gold electrode (AuE) modified with Ag metal-organic framework mesoporous carbon (Ag-MOF@MC) and molecularly imprinted polymers (MIPs). To that end, the MIP layer was formed on the Ag-MOF@MC by implanting Hb as the pattern molecule during the polymerization. The modified electrode was designed using electrochemical approaches including differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). Using a response level experimental design method, the most important parameters affecting the reaction of the sensing system including pH, incubation time, and scanning rate were optimized. Following the same route, the Hb concentration, pH, temperature, and elution times were optimized to prepare the imprinted polymer layer on the Ag-MOF@MC surface. By exploiting DPV techniques based on the optimal parameters, the electrochemical response of the AuE/Ag-MOF@MC-MIPs for Hb determination was recorded in a wide linear dynamic range (LDR) of 0.2 pM to 1000 nM, with a limit of detection (LOD) of 0.09 pM. Moreover, the Ag-MOF@MC-MIP sensing system showed good stability, high selectivity, and acceptable reproducibility for Hb determination. The sensing system was successfully applied for Hb determination in real blood samples, and the results were compared with those of the standard methods for Hb determination. Acceptable recovery (99.0%) and RDS% (4.6%) confirmed the applicability and reliability of the designed Hb sensing system.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据