4.7 Article

Development and validation of a UHPLC-MS/MS method to measure cefotaxime and metabolite desacetylcefotaxime in blood plasma: a pilot study suitable for capillary microsampling in critically ill children

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 413, 期 17, 页码 4483-4491

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-021-03411-7

关键词

UHPLC-MS/MS; Capillary microsampling; Cefotaxime; Desacetylcefotaxime; Bioanalysis

资金

  1. University of Queensland
  2. Australian National Health and Medical Research Council [APP1142757]
  3. Australian National Health and Medical Research Council Fellowship [APP1048652]

向作者/读者索取更多资源

Critical illness affects the pharmacokinetics of antibiotics, leading to potential ineffective exposure and antibiotic resistance. Lack of studies on antibiotic pharmacokinetics in critically ill children results in significant off-label dosing issues. A bioanalytical method using capillary microsampling was developed and validated for the quantification of cefotaxime and its metabolite in plasma samples from critically ill children.
Critical illness has been shown to affect the pharmacokinetics of antibiotics, which can lead to ineffective antibiotic exposure and the potential emergence of resistant bacteria. The lack of studies describing antibiotic pharmacokinetics in critically ill children has led to significant off-label dosing. This is, in part, due to the ethical and physiological challenges of removing frequent, large-volume samples from children. Capillary microsampling facilitates the collection of small volumes of blood samples to conduct clinical pharmacokinetic studies. A sensitive, rapid, and accurate ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) bioanalytical method to measure cefotaxime and desacetylcefotaxime in 2.8 mu L of plasma was developed and validated. Plasma samples were treated with acetonitrile and analytes were separated using a Kinetex C8 (100 x 2.1 mm) column. The chromatographic separation was established using a gradient method, with the mobile phases consisting of acetonitrile and ammonium acetate. An electrospray ionization source interface operated in a positive mode for the multiple reaction monitoring MS/MS analysis of cefotaxime, desacetylcefotaxime, and deuterated cefotaxime (internal standard). The bioanalytical method using microsample volumes met requirements for method validation for both analytes. Cefotaxime had precision within +/- 7.3% and accuracy within +/- 5% (concentration range of 0.5 to 500 mg/L). Desacetylcefotaxime had precision within +/- 9.5% and accuracy within +/- 3.5% (concentration range of 0.2 to 10 mg/L). The bioanalytical method was applied for the quantification of cefotaxime and its metabolite to 20 capillary microsamples collected at five time points in one dosing interval from five critically ill children.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据