4.5 Article

Comprehensive Analysis of Foulants in an Ultrafiltration Membrane Used for the Treatment of Bleach Plant Effluent in a Sulfite Pulp Mill

期刊

MEMBRANES
卷 11, 期 3, 页码 -

出版社

MDPI
DOI: 10.3390/membranes11030201

关键词

membrane fouling; lignin; hemicelluloses; polymeric membrane; ultrafiltration; magnesium

资金

  1. Banmark Oy

向作者/读者索取更多资源

Fouling is a major obstacle in introducing membrane processes in the pulping industry, requiring complementary analysis methods to improve processing conditions and enhance membrane performance.
Fouling is a major obstacle in the introduction of membrane processes in new applications in the pulping industry. Due to the complex nature of the feed solutions, complementary analysis methods are usually needed to identify the substances involved. Four different methods were used for the comprehensive analysis of a membrane removed from an ultrafiltration plant treating alkaline bleach plant effluent in a sulfite pulp mill to identify the substances causing fouling. Magnesium was detected both on the membrane surface and in the nonwoven membrane backing and a small amount of polysaccharides was detected after acid hydrolysis of the fouled membrane. This study provides information on foulants, which can be used to improve processing conditions and cleaning protocols and thus the membrane performance in pulp mill separation processes. It also provides an overview of the usefulness of various analytical methods.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据