4.6 Article

Design and Clinical Validation of a Robotic Ankle-Foot Simulator With Series Elastic Actuator for Ankle Clonus Assessment Training

期刊

IEEE ROBOTICS AND AUTOMATION LETTERS
卷 6, 期 2, 页码 3793-3800

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/LRA.2021.3065242

关键词

Medical robots and systems; haptics and haptic interfaces; education robotics; human-centered robotics; physical human-robot interaction

类别

资金

  1. University of Illinois at Urbana Champaign
  2. Zhejiang University

向作者/读者索取更多资源

A series elastic actuator (SEA) based haptic training simulator was proposed to provide a realistic and safe training environment for healthcare trainees learning the neurological examination technique to assess ankle clonus. The simulator accurately estimated interaction torque and closely tracked torque commands, demonstrating potential as an effective training tool. Evaluation by experienced physicians and physical therapists showed successful simulation of ankle clonus in different clinical states, indicating the simulator's worth as a training tool.
To fulfill the need for reliable and consistent medical training of the neurological examination technique to assess ankle clonus, a series elastic actuator (SEA) based haptic training simulator was proposed and developed. The simulator's mechanism (a hybrid of belt and linkage drive) and controller (impedance control) were designed to render a realistic and safe training environment. Benchtop tests demonstrated that the prototype simulator was able to accurately estimate the interaction torque from the trainee (average RMSE of 0.2 Nm) and closely track a chirp torque command up to 10 Hz (average RMSE of <0.22 Nm). The high-level impedance controller could switch between different clinically encountered states (i.e., no clonus, unsustained clonus, and sustained clonus) based on trainee's assessment technique. The simulator was evaluated by a group of 17 experienced physicians and physical therapists. Subjects were instructed to induce sustained clonus using their normal technique. The simulator was assessed in two common clinical positions (seated and supine). Subjects scored simulation realism on a variety of control features. To expedite controller design iteration, feedback from Day 1 was used to modify simulation parameters prior to testing on Day 2 with a new subject group. On average, all subjects could successfully trigger a sustained clonus response within 4-5 attempts in the first position and 2-3 in the second. Feedback on the fidelity of simulation realism improved between Day 1 and Day 2. Results suggest that this SEA-based simulator could he a viable training tool for healthcare trainees learning to assess ankle clonus.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据