4.7 Article

Investigating the energy flexibility of Dutch office buildings on single building level and building cluster level

期刊

JOURNAL OF BUILDING ENGINEERING
卷 40, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.jobe.2021.102687

关键词

Energy flexibility; Thermal mass; Aggregator; Building parameters; Thermal comfort control strategies; Characterization assessment

资金

  1. Dutch Technology Foundation STW [11854]
  2. Ministry of Economic Affairs
  3. Eindhoven University of Technology

向作者/读者索取更多资源

Demand Response is used to reduce the mismatch between renewable energy generation and electricity demand. Buildings can provide energy flexibility through their thermal mass, with factors such as thermal capacity and window to wall ratio having a significant impact. The study shows that in certain cases, the potential energy shiftable by the thermal mass of a building can be comparable to commercial battery capacity.
Demand Response is used to reduce the mismatch between electricity generation by renewable energy sources and electricity demand. Buildings are large energy consumers and can play an important role in matching generation and demand. Energy flexibility is defined as the ability of a building to manage its generation and demand according to local climate conditions, user needs and grid requirements. This article focuses on the thermal mass of buildings as a source of energy flexibility. The investigation is based on a characterization assessment method on single building level and on aggregator level. On single building level, different building parameters such as the thermal capacity of the construction, window to wall ratio, facade insulation and glazing properties are investigated and their impact on the energy flexibility is assessed. The thermal capacity and window to wall ratio are considered the most influential in the studied buildings. The characterization assessment shows a minimum 0.14 and a maximum 0.34 kWh/m(2) potential shiftable energy. The results of the characterization assessment method are compared with Demand Response events under more realistic conditions for specific case study buildings. The results show to be representative of the potential shiftable energy of a building envelope. The results show that in certain cases, the potential shiftable energy by the thermal mass of the building is comparable to the capacity of a commercial battery for utility buildings (232 kWh). Finally, the aggregated flexibility of clusters of Dutch office buildings is investigated and analogized to different electrical battery storage projects around the world. The results show that the thermal mass of 17 reference buildings show the potential of a storage capacity close to the biggest electrical battery projects in the Netherlands. The limitations of this study and advantages and disadvantages of electrical storage and thermal mass storage are discussed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据