4.6 Article

Application of One-Step Reverse Transcription Droplet Digital PCR for Dengue Virus Detection and Quantification in Clinical Specimens

期刊

DIAGNOSTICS
卷 11, 期 4, 页码 -

出版社

MDPI
DOI: 10.3390/diagnostics11040639

关键词

dengue virus; droplet digital PCR; virus detection; virus quantification

资金

  1. Faculty of Medicine Siriraj Hospital, Mahidol University [R015834004]
  2. Thailand Research Fund [RSA 5680049]
  3. Armed Forces Health Surveillance Division (AFHSD)-Global Emerging Infections Surveillance (GEIS) Branch
  4. Office of the Higher Education Commission
  5. Mahidol University under the National Research Universities Initiative
  6. Siriraj Chalermprakiat Grant, Faculty of Medicine Siriraj Hospital, Mahidol University
  7. Research Chair Grant, NSTDA, Thailand
  8. Research Lecturer Grant, Faculty of Medicine Siriraj Hospital, Mahidol University
  9. Royal Golden Jubilee Ph.D. Program [PHD/0101/2554]

向作者/读者索取更多资源

RT-ddPCR demonstrates superior sensitivity compared to qRT-PCR in detecting and quantifying DENV, with interlaboratory variations observed in quantification of DENV in clinical samples. This optimized protocol could potentially harmonize DENV quantification results and enhance disease severity correlation studies.
Detection and quantification of viruses in laboratory and clinical samples are standard assays in dengue virus (DENV) studies. The quantitative reverse transcription polymerase chain reaction (qRT-PCR) is considered to be the standard for DENV detection and quantification due to its high sensitivity. However, qRT-PCR offers only quantification relative to a standard curve and consists of several in-house components resulting in interlaboratory variations. We developed and optimized a protocol for applying one-step RT-droplet digital PCR (RT-ddPCR) for DENV detection and quantification. The lower limit of detection (LLOD95) and the lower limit of quantification (LLOQ) for RT-ddPCR were estimated to be 1.851 log10-copies/reaction and 2.337 log10-copies/reaction, respectively. The sensitivity of RT-ddPCR was found to be superior to qRT-PCR (94.87% vs. 90.38%, p = 0.039) while no false positives were detected. Quantification of DENV in clinical samples was independently performed in three laboratories showing interlaboratory variations with biases <0.5 log10-copies/mL. The RT-ddPCR protocol presented here could help harmonize DENV quantification results and improve findings in the field such as identifying a DENV titer threshold correlating with disease severity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据