4.7 Article

Fatty Acid Prediction in Bovine Milk by Attenuated Total Reflection Infrared Spectroscopy after Solvent-Free Lipid Separation

期刊

FOODS
卷 10, 期 5, 页码 -

出版社

MDPI
DOI: 10.3390/foods10051054

关键词

mid-infrared spectroscopy; attenuated total reflection; bovine milk; fatty acids; partial least squares

资金

  1. COMET Center CHASE [868615]
  2. BMVIT
  3. BMDW
  4. Federal Province of Upper Austria
  5. TUWien Bibliothek
  6. Federal Province of Vienna

向作者/读者索取更多资源

A novel approach for mid-IR based prediction of bovine milk fatty acid composition was introduced in this study using a rapid, solvent-free two-step centrifugation method along with ATR-FT-IR spectroscopy. The PLS regression models showed good predictions for fatty acid sum parameters and individual fatty acids, with significantly better performance compared to literature using whole milk transmission spectra. This combination of solvent-free lipid separation and ATR-FT-IR spectroscopy represents a fast and high-throughput method for fatty acid prediction.
In the present study, a novel approach for mid-infrared (IR)-based prediction of bovine milk fatty acid composition is introduced. A rapid, solvent-free, two-step centrifugation method was applied in order to obtain representative milk fat fractions. IR spectra of pure milk lipids were recorded with attenuated total reflection Fourier-transform infrared (ATR-FT-IR) spectroscopy. Comparison to the IR transmission spectra of whole milk revealed a higher amount of significant spectral information for fatty acid analysis. Partial least squares (PLS) regression models were calculated to relate the IR spectra to gas chromatography/mass spectrometry (GC/MS) reference values, providing particularly good predictions for fatty acid sum parameters as well as for the following individual fatty acids: C10:0 (R-P(2) = 0.99), C12:0 (R-P(2) = 0.97), C14:0 (R-P(2) = 0.88), C16:0 (R-P(2) = 0.81), C18:0 (R-P(2) = 0.93), and C18:1cis (R-P(2) = 0.95). The IR wavenumber ranges for the individual regression models were optimized and validated by calculation of the PLS selectivity ratio. Based on a set of 45 milk samples, the obtained PLS figures of merit are significantly better than those reported in literature using whole milk transmission spectra and larger datasets. In this context, direct IR measurement of the milk fat fraction inherently eliminates covariation structures between fatty acids and total fat content, which poses a common problem in IR-based milk fat profiling. The combination of solvent-free lipid separation and ATR-FT-IR spectroscopy represents a novel approach for fast fatty acid prediction, with the potential for high-throughput application in routine lab operation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据