Optimal probabilistic location of DGs using Monte Carlo simulation based different bio-inspired algorithms

期刊

AIN SHAMS ENGINEERING JOURNAL
卷 12, 期 3, 页码 2735-2762

出版社

ELSEVIER
DOI: 10.1016/j.asej.2021.02.007

关键词

Optimal allocation; Monte Carlo simulation; Bio-inspired algorithm; Distributed generators; GWO; MRFO; SBO; WOA

资金

  1. Taif University, Taif, Saudi Arabia [TURSP-2020/146]

向作者/读者索取更多资源

The paper presents a study on optimizing the location of distributed generators under load uncertainties using Monte Carlo simulation integrated with different bio-inspired algorithms, and compares the performance of four bio-inspired algorithms. Through experimental research, the superiority of different algorithms was evaluated.
Stochastic nature of load demand has a great impact on the performance of electrical power system. As a result, planning of electrical power system considering load uncertainties became inevitable. This paper presents Monte Carlo simulation based different bio-inspired algorithms, grey wolf optimization (GWO), manta ray foraging optimization (MRFO), satin bower bird optimization (SBO) and whale optimization (WOA) to optimize locations of three DG units under load uncertainties considering 500 scenarios. Each scenario includes 50 iterations which means that for each run we have 25,000 iterations and 500 characteristics for different load value. Two objectives are achieved. Firstly, statistically finding the optimal probabilistic location of three DG units under load uncertainties in IEEE 33-bus and IEEE 69-bus radial distribution system based on Monte Carlo simulation integrated with different bio-inspired algorithms. Secondly, comparing between the performances of four different bio-inspired algorithms. Three objective functions are considered, minimizing active power loss, minimizing voltage deviation and maximizing voltage stability index. The active and reactive power demand are normally distributed using normal distribution function. The optimal probabilistic location is investigated considering two cases under load uncertainties, optimizing location of three DG units generally and optimizing location of one DG unit assuming two optimum locations for the other two units extracted from case I. The obtained results (after placing DG units) are compared to the base case (DG units are not connected) and compared to each other according to the optimization technique. The results show that, SBO algorithm superiors other algorithms almost in all cases. Comes next GWO which provide good results generally. However, the good performance obtained by MRFO, it consumes twice the time of other algorithms. WOA however fast convergence, it provides results worse than other algorithms. The system is applied to the wellknown IEEE 33-bus and IEEE 69-bus radial distribution system. (C) 2021 THE AUTHORS. Published by Elsevier BV on behalf of Faculty of Engineering, Ain Shams University.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据