4.6 Article

Near-Infrared Spectroscopy Assessment of Tissue Oxygenation During Selective Cerebral Perfusion for Neonatal Aortic Arch Reconstruction

期刊

FRONTIERS IN MEDICINE
卷 8, 期 -, 页码 -

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fmed.2021.637257

关键词

selective cerebral perfusion; cardiopulmonary bypass; hypothermia; near-infrared tissue saturation; aortic arch surgery

资金

  1. Ministry of Science and Technology in Taiwan [MOST-1092314-B-002-216]

向作者/读者索取更多资源

The study focused on optimal selective cerebral perfusion (SCP) management during neonatal aortic arch surgery. Mild hypothermia was induced during SCP, and tissue oxygenation monitor was used during cardiopulmonary bypass (CPB) to ensure adequate perfusion. Results showed efficient maintenance of brain perfusion with SCP, but demonstrated contrasting effects on renal and lower extremity tissue oxygenation during the surgery.
Objective: Optimal selective cerebral perfusion (SCP) management for neonatal aortic arch surgery has not been extensively studied. We induced mild hypothermia during SCP and used the tissue oxygenation monitor to ensure adequate perfusion during the cardiopulmonary bypass (CPB). Methods: Eight cases were recruited from September 2018 to April 2020. SCP was maintained at 30 degrees C, and CPB was adjusted to achieve a mean right radial artery pressure of 30 mmHg. The near-infrared tissue saturation (NIRS) monitor was applied to assess the right and left brain, flank, and lower extremity during the surgery. Results: During surgery, the mean age was 4.75 days, the mean body weight was 2.92 kg, the CPB duration was 86.5 +/- 18.7 min, the aortic cross-clamp time was 46.1 +/- 12.7 min, and the SCP duration was 14.6 +/- 3.4 min. The brain NIRS before, during, and after SCP was 64.2, 67.2, and 71.5 on the left side and 67.9, 66.2, and 70.1 on the right side (p = NS), respectively. However, renal and lower extremity tissue oxygenation, respectively decreased from 61.6 and 62.4 before SCP to 37.7 and 39.9 after SCP (p < 0.05) and then increased to 70.1 and 90.4 after full body flow resumed. No stroke was reported postoperatively. Conclusion: SCP under mild hypothermia can aid in efficient maintenance of brain perfusion during neonatal arch reconstruction. The clinical outcome of this strategy was favorable for up to 20 min, but the safety duration of lower body ischemia warrants further analysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据