4.6 Article

Vasopressin Loading for Refractory Septic Shock: A Preliminary Analysis of a Case Series

期刊

FRONTIERS IN MEDICINE
卷 8, 期 -, 页码 -

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fmed.2021.644195

关键词

critical care; septic shock; sepsis; vasopressin; loading

向作者/读者索取更多资源

This study examined the effects of vasopressin loading followed by continuous administration in septic shock patients and found that loading may predict responses to continuous administration. However, further investigation involving safety analysis is needed.
Background: Vasopressin is one of the strong vasopressor agents associated with ischemic events. Responses to the administration of vasopressin differ among patients with septic shock. Although the administration of a high dose of vasopressin needs to be avoided, the effects of bolus loading have not yet been examined. Since the half-life of vasopressin is longer than that of catecholamines, we hypothesized that vasopressin loading may be effective for predicting responses to its continuous administration. Methods: We retrospectively analyzed consecutive cases of septic shock for which vasopressin was introduced with loading under noradrenaline at >0.2 mu g/kg/min during the study period. Vasopressin was administered in a 1 U bolus followed by its continuous administration at 1 U/h. The proportion of patients with a negative catecholamine index (CAI) change 6 h after the introduction of vasopressin was set as the primary outcome. We defined non-responders for exploration as those with a mean arterial pressure change <18 mmHg 1 min after vasopressin loading, among whom none had a change in CAI Results: Twenty-one consecutive cases were examined in the present study, and included 14 responders and 7 non-responders. The primary outcome accounted for 71.4% of responders and 0% of non-responders, with a significant difference (p = 0.0039). Median CAI changes 2, 4, and 6 h after the administration of vasopressin were 0, -5, and -10 in responders and +20, +10, and +10 in non-responders, respectively. CAI was not reduced in any non-responder. Outcomes including mortality were not significantly different between responders and non-responders. Digital ischemia (1/21) and mesenteric ischemia (1/21) were observed. Conclusions: Vasopressin loading may predict responses to its continuous administration in septic shock patients. Further investigations involving a safety analysis are needed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据