Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment

期刊

QUANTITATIVE IMAGING IN MEDICINE AND SURGERY
卷 11, 期 5, 页码 1723-1736

出版社

AME PUBL CO
DOI: 10.21037/qims-20-814

关键词

Aortic dissection; maximal diameter; volume; aortic remodeling; computed tomography angiography

资金

  1. Royal Society [NA170094/IF003-2018, IIRG024B2019]
  2. University Malaysia Pahang (UMP) Post-Doctoral Fellowship in Research

向作者/读者索取更多资源

The study aimed to analyze the correlation between maximal luminal diameters and volume changes in true and false lumens after stent-grafting for Stanford type B aortic dissection. Results showed that volume measurements were more sensitive in identifying lumen expansion or shrinkage at the distal stented region.
Background: The study aims to analyze the correlation between the maximal diameter (both axial and orthogonal) and volume changes in the true (TL) and false lumens (FL) after stent-grafting for Stanford type B aortic dissection. Method: Computed tomography angiography was performed on 13 type B aortic dissection patients before and after procedure, and at 6 and 12 months follow-up. The lumens were divided into three regions: the stented area (Region 1), distal to the stent graft to the celiac artery (Region 2), and between the celiac artery and the iliac bifurcation (Region 3). Changes in aortic morphology were quantified by the increase or decrease of diametric and volumetric percentages from baseline measurements. Results: At Region 1, the TL diameter and volume increased (pre-treatment: volume = 51.4 +/- 41.9 mL, maximal axial diameter = 22.4 +/- 6.8 mm, maximal orthogonal diameter = 21.6 +/- 7.2 mm; follow-up: volume = 130.7 +/- 69.2 mL, maximal axial diameter = 40.1 +/- 8.1 mm, maximal orthogonal diameter = 31.9+2.6 mm, P<0.05 for all comparisons), while FL decreased (pre-treatment: volume = 129.6 +/- 150.5 mL; maximal axial diameter = 43.0 +/- 15.8 mm; maximal orthogonal diameter = 28.3 +/- 12.6 mm; follow-up: volume = 66.6 +/- 95.0 mL, maximal axial diameter = 24.5 +/- 19.9 mm, maximal orthogonal diameter = 16.9 +/- 13.7, P<0.05 for all comparisons). Due to the uniformity in size throughout the vessel, high concordance was observed between diametric and volumetric measurements in the stented region with 93% and 92% between maximal axial diameter and volume for the true/false lumens, and 90% and 92% between maximal orthogonal diameter and volume for the true/false lumens. Large discrepancies were observed between the different measurement methods at regions distal to the stent graft, with up to 46% differences between maximal orthogonal diameter and volume. Conclusions: Volume measurement was shown to be a much more sensitive indicator in identifying lumen expansion/shrinkage at the distal stented region.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据