4.6 Article

Automated Non-Coplanar VMAT for Dose Escalation in Recurrent Head and Neck Cancer Patients

期刊

CANCERS
卷 13, 期 8, 页码 -

出版社

MDPI
DOI: 10.3390/cancers13081910

关键词

HyperArc; SBRT; reirradiation; recurrent head and neck cancer; non-coplanar VMAT

类别

资金

  1. Varian Medical Systems through the prospective clinical study [NCT03892720]

向作者/读者索取更多资源

The study evaluates the potential for tumor dose escalation in recurrent head and neck cancer patients using the HyperArc technique, showing that it significantly increases tumor dose while maintaining minimal risk to nearby organs.
Simple Summary The ability to escalate the radiation dose to head and neck tumors has been shown to offer improved local control, and consequently, survival for recurrent head and neck cancer (rHNC) patients. This study evaluates the HyperArc automated non-coplanar planning technique (originally developed for intracranial treatment) for 20 rHNC patients, and compares this technique to conventional planning methods. HyperArc enables significant tumor dose escalation, with average increases in mean target dose of over 11.5 Gy (26%), while maintaining clinically-equivalent doses to nearby organs. Our results show that the average probability of tumor control is 23% higher for HyperArc than conventional techniques. This study evaluates the potential for tumor dose escalation in recurrent head and neck cancer (rHNC) patients with automated non-coplanar volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) planning (HyperArc). Twenty rHNC patients are planned with conventional VMAT SBRT to 40 Gy while minimizing organ-at-risk (OAR) doses. They are then re-planned with the HyperArc technique to match these minimal OAR doses while escalating the target dose as high as possible. Then, we compare the dosimetry, tumor control probability (TCP), and normal tissue complication probability (NTCP) for the two plan types. Our results show that the HyperArc technique significantly increases the mean planning target volume (PTV) and gross tumor volume (GTV) doses by 10.8 +/- 4.4 Gy (25%) and 11.5 +/- 5.1 Gy (26%) on average, respectively. There are no clinically significant differences in OAR doses, with maximum dose differences of <2 Gy on average. The average TCP is 23% (+/- 21%) higher for HyperArc than conventional plans, with no significant differences in NTCP for the brainstem, cord, mandible, or larynx. HyperArc can achieve significant tumor dose escalation while maintaining minimal OAR doses in the head and neck-potentially enabling improved local control for rHNC SBRT patients without increased risk of treatment-related toxicities.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论