4.6 Article

Fabrication of Lensed Optical Fibers for Biosensing Probes Using CO2 and Femtosecond Lasers

期刊

APPLIED SCIENCES-BASEL
卷 11, 期 9, 页码 -

出版社

MDPI
DOI: 10.3390/app11093738

关键词

CO2 laser; femtosecond laser; lensed fiber; fiber cleaving

资金

  1. Chosun University
  2. Ministry of Education, Science & Technology (MoST), Republic of Korea [gist-20] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  3. Ministry of Science, ICT & Future Planning, Republic of Korea [GIST-20] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  4. Ministry of Science & ICT (MSIT), Republic of Korea [GIST-04, GIST] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

A new method for fabricating a lensed fiber with a desired focal length using femtosecond and CO2 lasers is proposed, achieving greater precision and efficiency compared to conventional methods.
We propose a new method for precisely fabricating a lensed fiber with a desired focal length by first cleaving a coreless silica fiber using an ultrafast femtosecond laser without thermal effects and subsequently shaping the radius of curvature at the optical-fiber end using a CO2 laser. The precisely cleaved segment of the coreless silica fiber obtained with the femtosecond laser is attached to a long single-mode fiber. The beam-exposure time and laser power of the CO2 laser are adjusted to melt the coreless-fiber end to yield a uniform, consistent, and precise radius of curvature, thereby realizing a lensed optical fiber. The precision of the radius of curvature in this case is greater than those obtained with the conventional arc discharge method with thermal treatment requiring fairly complex processes and yielding relatively low fabrication accuracy. In our study, we observe a difference between the measured and calculated focal lengths of the fabricated lens, possibly because the exact value of the mode field diameter is uncertain. On the other hand, the beam size measured using the knife-edge method matches closely with the theoretical size. Our findings confirm the feasibility of fabricating lensed optical fibers for fiber-based biosensing using CO2 and femtosecond lasers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据