4.6 Article

Sharp Changes in Muscle Tone in Humans Under Simulated Microgravity

期刊

FRONTIERS IN PHYSIOLOGY
卷 12, 期 -, 页码 -

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fphys.2021.661922

关键词

muscle tone; atony; MyotonPRO; Dry Immersion; microgravity; space flight

资金

  1. Russian Science Foundation [19-15-00435]
  2. Russian Science Foundation [19-15-00435] Funding Source: Russian Science Foundation

向作者/读者索取更多资源

This study aimed to assess changes in muscle tone in a microgravity environment, using the MyotonPRO device to measure multiple muscles. Variations in muscle tone responses were observed among different muscles in Dry Immersion experiments.
A decrease in muscle tone induced by space flight requires a standardized assessment of changes to control the state of the neuromuscular system. This study is a step toward the development of a unified protocol, aimed at determining the initial effect of the presence or withdrawal of support on muscle tone, the effects of a 2-h supportlessness in Dry Immersion (DI) experiments, and the changes in muscle tone depending on the site of measurement. To perform measurements of changes in muscle tone, we used a MyotonPRO device. The list of muscles that we assessed includes: trunk - mm. deltoideus posterior, trapezius, erector spinae; leg - mm. biceps femoris, rectus femoris, tibialis anterior, soleus, gastrocnemius; foot - m. flexor digitorum brevis, tendo Achillis, aponeurosis plantaris. The study involved 12 healthy volunteers (6 men, 6 women) without musculoskeletal disorders and aged 32.8 +/- 1.6 years. At the start of DI, there was a significant decrease in muscle tone of the following muscles: mm. tibialis anterior (-10.9%), soleus (-9.6%), erector spinae (-14.4%), and the tendo Achillis (-15.3%). The decrease continued to intensify over the next 2 h. In contrast, the gastrocnemius muscle demonstrated an increase in muscle tone (+7.5%) 2 h after the start of DI compared to the immediate in-bath baseline. Muscle tone values were found to be site-dependent and varied in different projections of mm. erector spinae and soleus. In previous experiments, we observed a high sensitivity of the myotonometry technique, which was confirmed in this study. To make it possible to compare data from different studies, a standardized protocol for measuring muscle tone for general use in gravitational physiology needs to be developed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据