4.5 Article

Underwater photogrammetry for close-range 3D imaging of dry-sensitive objects: The case study of cephalopod beaks

期刊

ECOLOGY AND EVOLUTION
卷 11, 期 12, 页码 7730-7742

出版社

WILEY
DOI: 10.1002/ece3.7607

关键词

3D models; cephalopod beaks; dry‐ sensitive material; micro‐ CT scanning; micro‐ photogrammetry; underwater photogrammetry

向作者/读者索取更多资源

Researchers have developed a new underwater photogrammetry protocol to reconstruct 3D models of dry-sensitive objects such as cephalopod beaks, providing a fast, efficient, and accurate method for quantitative morphological analysis.
Technical advances in 3D imaging have contributed to quantifying and understanding biological variability and complexity. However, small, dry-sensitive objects are not easy to reconstruct using common and easily available techniques such as photogrammetry, surface scanning, or micro-CT scanning. Here, we use cephalopod beaks as an example as their size, thickness, transparency, and dry-sensitive nature make them particularly challenging. We developed a new, underwater, photogrammetry protocol in order to add these types of biological structures to the panel of photogrammetric possibilities. We used a camera with a macrophotography mode in a waterproof housing fixed in a tank with clear water. The beak was painted and fixed on a colored rotating support. Three angles of view, two acquisitions, and around 300 pictures per specimen were taken in order to reconstruct a full 3D model. These models were compared with others obtained with micro-CT scanning to verify their accuracy. The models can be obtained quickly and cheaply compared with micro-CT scanning and have sufficient precision for quantitative interspecific morphological analyses. Our work shows that underwater photogrammetry is a fast, noninvasive, efficient, and accurate way to reconstruct 3D models of dry-sensitive objects while conserving their shape. While the reconstruction of the shape is accurate, some internal parts cannot be reconstructed with photogrammetry as they are not visible. In contrast, these structures are visible using reconstructions based on micro-CT scanning. The mean difference between both methods is very small (10(-5) to 10(-4) mm) and is significantly lower than differences between meshes of different individuals. This photogrammetry protocol is portable, easy-to-use, fast, and reproducible. Micro-CT scanning, in contrast, is time-consuming, expensive, and nonportable. This protocol can be applied to reconstruct the 3D shape of many other dry-sensitive objects such as shells of shellfish, cartilage, plants, and other chitinous materials.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据