期刊
MATERIALS
卷 14, 期 8, 页码 -出版社
MDPI
DOI: 10.3390/ma14081893
关键词
platinum; cobalt; electroless deposition; EQCM
类别
资金
- Research Council of Lithuania (LMTLT) [TEC-06/2015]
The kinetics of electroless deposition of Pt using a cobalt ion redox system as a reducing agent was investigated in this study. Factors such as pH, concentration of reactants, temperature, and bubbling with argon were found to significantly affect the Pt deposition rate. Bubbling the electroless Pt plating solution with argon during the deposition process resulted in a higher deposition rate compared to not bubbling.
In the present work, the kinetics of electroless deposition of Pt, using a cobalt ion redox system (Co3+/Co2+) as a reducing agent, has been investigated. The deposition rate of Pt depends on the pH, concentration of reactants, and temperature. The deaeration and bubbling of the plating solution with argon play an essential role. It was found that 0.11 mg cm(-2) of Pt films could be deposited on the surface of a roughed glass sheet in one hour without replenishing the solution. Additional data have been obtained on the grounds of electrochemical quartz crystal microbalance experiments. The bubbling (agitation) of the electroless Pt plating solution with argon during the deposition of Pt results in a higher deposition rate and is ca. 3 mu g cm(-2) min(-1). The Pt deposition rate is far less, and is as low as 0.14 mu g cm(-2) min(-1) when the electroless Pt plating solution is not bubbled with argon during the deposition of Pt.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据