4.8 Article

Beam image-shift accelerated data acquisition for near-atomic resolution single-particle cryo-electron tomography

期刊

NATURE COMMUNICATIONS
卷 12, 期 1, 页码 -

出版社

NATURE PORTFOLIO
DOI: 10.1038/s41467-021-22251-8

关键词

-

资金

  1. Intramural Research Program of the NIH
  2. National Institute of Environmental Health Sciences [ZIC ES103326, ZO1 ES101905]
  3. National Science Foundation as part of the National Nanotechnology Coordinated Infrastructure (NNCI) [ECCS-2025064]

向作者/读者索取更多资源

The authors present a beam image-shift electron cryo-tomography (BISECT) approach that accelerates data collection speed and improves map resolution compared to earlier methods. They also demonstrate the in vitro structure of a 300kDa protein complex at 3.6 angstrom resolution as a test case.
Tomographic reconstruction of cryopreserved specimens imaged in an electron microscope followed by extraction and averaging of sub-volumes has been successfully used to derive atomic models of macromolecules in their biological environment. Eliminating biochemical isolation steps required by other techniques, this method opens up the cell to in-situ structural studies. However, the need to compensate for errors in targeting introduced during mechanical navigation of the specimen significantly slows down tomographic data collection thus limiting its practical value. Here, we introduce protocols for tilt-series acquisition and processing that accelerate data collection speed by up to an order of magnitude and improve map resolution compared to existing approaches. We achieve this by using beam-image shift to multiply the number of areas imaged at each stage position, by integrating geometrical constraints during imaging to achieve high precision targeting, and by performing per-tilt astigmatic CTF estimation and data-driven exposure weighting to improve final map resolution. We validated our beam image-shift electron cryo-tomography (BISECT) approach by determining the structure of a low molecular weight target (similar to 300kDa) at 3.6 angstrom resolution where density for individual side chains is clearly resolved. Tomographic reconstructions of cryopreserved specimens enable in-situ structural studies. Here, the authors present the beam image-shift electron cryo-tomography (BISECT) approach that accelerates data collection speed and improves the map resolution compared to earlier approaches and present the in vitro structure of a 300kDa protein complex that was solved at 3.6 angstrom resolution as a test case.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据