This study presents and analyzes a highly sensitive refractive index sensor based on a microfluidic channel and Ag-graphene composite nanowire, achieving maximum wavelength and amplitude sensitivity of 13700 nm/RIU and 1026 RIU-1. The sensor not only solves oxidation issues, but also enhances sensitivity, providing better performance than similar sensors. Additionally, the study thoroughly investigates the effects of various parameters on the sensor's performance, laying groundwork for the design of real-time, highly sensitive, remote sensing, and distributed SPR based RI sensor.
A highly sensitive refractive index (RI) sensor based on a microfluidic channel (MFC) incorporated in a single-mode fiber (SMF), filled with Ag-graphene composite nanowire is presented and analyzed here. The sensing performance and the coupling properties of designed sensor are numerically analyzed by using a full vectorial finite element method (FEM) incorporating amplitude and wavelength interrogation techniques in the detection range varied from n(a) = 1.330-1.350. The maximum wavelength and amplitude sensitivity are obtained of 13700 nm/RIU and 1026 RIU-1, respectively. Here, the Ag-graphene composite nanowire can not only solve the problem of oxidation but also enhances the sensitivity of the sensor. In addition of high sensitivity, it also provides better performance than other sensing devices based on similar technologies such as Ag nanowire-filled sensors. Moreover, the influences of polishing depth (D), nanowire radius (r(n)), graphene layer (L-g) and channel size (s) on the designed sensor, are also thoroughly investigated here. The present work can provide a base for designing a real-time, highly sensitivity, remote sensing, and distributed SPR based RI sensor.