4.6 Article

Development and Clinical Evaluation of an Immunochromatography-Based Rapid Antigen Test (GenBody™ COVAG025) for COVID-19 Diagnosis

期刊

VIRUSES-BASEL
卷 13, 期 5, 页码 -

出版社

MDPI
DOI: 10.3390/v13050796

关键词

SARS-CoV-2; nucleocapsid; antigen detection test; RT-PCR; immunochromatography

类别

资金

  1. Priority Research Centers Program through the National Research Foundation of Korea (NRF) - Ministry of Education [NRF-2015R1A6A1A 03032236]

向作者/读者索取更多资源

Antigen tests for SARS-CoV-2 offer a simpler and faster alternative to molecular tests, and clinical validation is crucial before widespread use. The GenBody (TM) COVAG025 immunoassay showed high sensitivity and specificity in both retrospective and prospective clinical studies, indicating its potential to assist in accurate diagnosis, isolation, and treatment of COVID-19 patients for better pandemic control.
Antigen tests for SARS-CoV-2 diagnosis are simpler and faster than their molecular counterparts. Clinical validation of such tests is a prerequisite before their field applications. We developed and clinically evaluated an immunochromatographic immunoassay, GenBody (TM) COVAG025, for the rapid detection of SARS-CoV-2 nucleocapsid (NP) antigen in two different clinical studies. Retrospectively, 130 residual nasopharyngeal swabs transferred in viral transport medium (VTM), pre-examined for COVID-19 through emergency use authorization (EUA)-approved real-time RT-PCR assay and tested with GenBody (TM) COVAG025, revealed a sensitivity and specificity of 90.00% (27/30; 95% CI: 73.47% to 97.89%) and 98.00% (98/100; 95% CI: 92.96% to 99.76%), respectively, fulfilling WHO guidelines. Subsequently, the prospective examination of 200 symptomatic and asymptomatic nasopharyngeal swabs, collected on site and tested with GenBody (TM) COVAG025 and EUA-approved real-time RT-PCR assay simultaneously, revealed a significantly higher sensitivity and specificity of 94.00% (94/100; 95% CI: 87.40% to 97.77%) and 100.00% (100/100; 95% CI: 96.38% to 100.00%), respectively. Clinical sensitivity and specificity were significantly high for samples with Ct values <= 30 as well as within 3 days of symptom onset, justifying its dependency on the viral load. Thus, it is assumed this can help with the accurate diagnosis and timely isolation and treatment of patients with COVID-19, contributing to better control of the global pandemic.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据