4.6 Article

Ureteral navigation using a fluorescent ureteral catheter during laparoscopic colorectal surgery

期刊

出版社

SPRINGER
DOI: 10.1007/s00464-021-08538-3

关键词

Fluorescence; Ureter; Navigation; Colorectal cancer; Laparoscopic surgery

类别

向作者/读者索取更多资源

This study evaluated the intraoperative utility of NIRFUC in 20 patients undergoing colorectal surgery. The ureters were clearly identified without the need for dissection, and there were no cases of ureteral injury. Fluorescence ureteral navigation using NIRFUC may facilitate colorectal surgery, especially in complex cases.
Background Ureteral injury is the most common urological complication of pelvic surgery, with a reported incidence during colon resection of 0.3-1.5%. Ureteral stenting is commonly performed preoperatively to prevent ureteral injury. Because tactile sensation is not reliable during laparoscopic surgery, the effect of the ureteral stent is considered limited. Recently, fluorescence imaging has been used in laparoscopic surgery. The Near-Infrared Ray Catheter (NIRC (TM)) fluorescent ureteral catheter (NIRFUC) is a new catheter with built-in NIR fluorescent resin. This pilot study was performed to evaluate the utility of fluorescence ureteral navigation using the NIRFUC during laparoscopic colorectal surgery. Methods We evaluated the intraoperative utility of the NIRFUC and the short-term outcomes in 20 patients treated with colorectal surgery at Kawaguchi Municipal Medical Center between February and July 2020. In all, 18 patients with malignant tumors and 2 patients with benign disease, i.e., a sigmoid colovesical fistula, were included. Ten patients developed preoperative intestinal obstruction. One patient experienced preoperative perforation. Nine patients developed preoperative peritumoral abscesses. Laparoscopic surgery was performed with the VISERA ELITE2 system. Results In all cases, the ureters were very clearly identified as fluorescent without the need for dissection. In all cases, only a moment was required to identify the ureter by fluorescence observation. In all cases, R0 resection was performed. The mean surgical duration was 334 min (161-1014), the mean blood loss was 10 ml (1-500), and the mean postoperative hospital stay was 11 days (8-47). There were no cases of ureteral injury. Conclusion The NIRFUC was very clearly identified as fluorescent in a moment during surgery without dissection around the ureter. Fluorescence ureteral navigation using the NIRFUC may make colorectal surgery easier and facilitate completion of complex minimally invasive surgery, especially during surgery in patients with invasion of the surrounding tissue or a history of pelvic surgery or radiation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据