4.7 Article

Demonstration of the enhancement of gate bias and ionic strength in electric-double-layer field-effect-transistor biosensors

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 334, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2021.129567

关键词

Enhanced electric-double-layer (EnEDL); Impedance analysis; Field-effect transistors (FETs); Biosensors; Extended gate

资金

  1. Ministry of Science Technology [MOST 108-2221-E-009-085, MOST 108-2218-E-007-012]
  2. National Tsing Hua University [108QI034E1]

向作者/读者索取更多资源

This study investigates the mechanism of enhanced electric-double-layer field-effect-transistor biosensors for protein detection in high ionic strength solutions. By enhancing capacitance, optimizing gate voltage and salt concentration, and utilizing AC impedance measurement, the sensitivity of the biosensors can be increased, allowing for direct protein detection within 5 minutes without complex sample dilution.
In this study, we investigate the mechanism of enhanced electric-double-layer (EnEDL) field-effect-transistor (FET)-based biosensors, which can successfully detect proteins in high ionic strength solution, such as in 1XPBS. This EnEDL FET biosensor performs good sensitivity in high ionic strength solution by creating enhanced capacitance in the EDL with higher gate voltage or higher salt concentration, and operating in a large trans conductance of the FET to amplify the signal. AC impedance measurement is also introduced and identifies that the imaginary part dominates the sensitivity of C-reactive protein (CRP) detection, indicating that the EnEDL capacitance plays the key role in the sensing mechanism. Extended gate connecting to the FET and a separated gate electrode is fabricated and biased with the gate voltage for the EnEDL FET biosensors. The test solution is placed between the two electrodes, and the voltage drop across the solution caused by CRP concentration was analyzed for different gate voltages and salt concentrations for the EnEDL FET biosensors. The results show that as the EDL is enhanced by higher gate bias or higher salt concentration, the sensitivity is increased, either in AC impedance analysis or voltage drop in the test solution. To utilize the enhanced EDL, the maximum trans conductance of the FET should be located in a larger gate voltage. This technology can allow direct protein detection in 5 min. without complex dilution of clinical samples, which is promising for portable devices for personal healthcare.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据