4.7 Article

Comparative evaluation of simultaneous nitritation/denitritation and energy recovery in air-cathode microbial fuel cells (ACMFCs) treating low C/N ratio wastewater

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 788, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.scitotenv.2021.147652

关键词

ACMFCs; Low C/N ratio wastewater (LCNW); SND; Energy recovery; Pollutant removal; Co-occurrence analysis

资金

  1. National Natural Science Foundation of China [51908144, 31970106]
  2. West Light Foundation of CAS [2017XBZG_XBQNXZ_A1007]
  3. Youth Innovation Promotion Association Foundation of CAS [20180404]
  4. Talent Project of Organization Department of the CPC Sichuan Committee

向作者/读者索取更多资源

Air-cathode microbial fuel cells (ACMFCs) have shown successful treatment of low C/N ratio wastewater (LCNW) with high pollutant removal rates and sustainable current generation. The study demonstrated that low C/N ratios promote simultaneous nitritation/denitritation (SND) by balancing nitritation and denitritation, with considerable nitrifiers and denitrificans enriched in the ACMFCs contributing to SND and power recovery. Optimal control of parameters such as COD, NH4+-N, PBS, Rext, and C/N ratio is necessary for efficient SND in ACMFCs for LCNW treatment.
Air-cathode microbial fuel cells (ACMFCs) can extract available electrons from the low C/N ratio wastewater (LCNW) for pollutant degradation and power generation. However, the multiple effects of operating parameters and their relationship between the performances and parameters are still lacking. In this study, several ACMFCs for simultaneous nitritation/denitritation (SND) and energy recovery were constructed and evaluated in terms of chemical oxygen demand (COD), NH4+-N, C/N ratio, phosphate buffer solution (PBS), and external resistance (Rext), and several derived parameters (e.g., organic loading rate (OLR), nitrogen loading rate (NLR)). Results indicated that ACMFCs could be used to treat LCNW successfully with high pollutant removal rates and sustainable current generation. Maximum removal efficiencies of 94% COD, 92% NH4+-N, and 92% total nitrogen (TN) were achieved. A maximum power density of 1400 mW m(-2) and columbic efficiency of 69.2% were also obtained at achieved. A maximum power density of 1400 mW m(-2) and columbic efficiency of 69.2% were also obtained at a low C/N ratio of 1.7-2.6. Low C/N ratios promoted SND by balancing nitritation and denitritation. The microbial community and their predicated function results showed considerable nitrifiers and denitrificans were enriched in the ACMFCs, contributing to SND and power recovery. Further analyses showed that the NH4+-N could inhibit SND, but PBS and Rext had no obvious effects on this outcome. Co-occurrence network analysis demonstrated that power is positively correlated with COD and Rext; strong correlations between organic removal and COD, and be-tween nitrogen removal and ammonia, conductivity, and C/N ratio were also noted. Overall, the appropriate con-trol of such parameters is necessary to achieve efficient SND in ACMFCs for LCNW treatment. (C) 2021 Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据