4.5 Article

Method of computing direction-dependent margins for the development of consensus contouring guidelines

期刊

RADIATION ONCOLOGY
卷 16, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s13014-021-01799-1

关键词

Consensus contouring; Clinical target volume margins; Interobserver variability; Stereotactic body radiotherapy

资金

  1. Natural Sciences and Engineering Research Council (NSERC) [RGPIN-2017-06596, CRD 507521-16]
  2. NSERC CGS D scholarship
  3. Walter C. Sumner Memorial Fellowship

向作者/读者索取更多资源

This study demonstrates a novel method for quantifying CTV margins and interobserver variability in clinician-specified directions. The recommended intraosseous and extraosseous margins were found to be 7.0 mm and 8.0 mm, respectively. The median coefficient of variation quantifying the margin disagreement between experts was 0.59 and 0.48 for intraosseous and extraosseous disease.
Background Clinical target volume (CTV) contouring guidelines are frequently developed through studies in which experts contour the CTV for a representative set of cases for a given treatment site and the consensus CTVs are analyzed to generate margin recommendations. Measures of interobserver variability are used to quantify agreement between experts. In cases where an isotropic margin is not appropriate, however, there is no standard method to compute margins in specified directions that represent possible routes of tumor spread. Moreover, interobserver variability metrics are often measures of volume overlap that do not account for the dependence of disagreement on direction. To aid in the development of consensus contouring guidelines, this study demonstrates a novel method of quantifying CTV margins and interobserver variability in clinician-specified directions. Methods The proposed algorithm was applied to 11 cases of non-spine bone metastases to compute the consensus CTV margin in each direction of intraosseous and extraosseous disease. The median over all cases for each route of spread yielded the recommended margins. The disagreement between experts on the CTV margin was quantified by computing the median of the coefficients of variation for intraosseous and extraosseous margins. Results The recommended intraosseous and extraosseous margins were 7.0 mm and 8.0 mm, respectively. The median coefficient of variation quantifying the margin disagreement between experts was 0.59 and 0.48 for intraosseous and extraosseous disease. Conclusions The proposed algorithm permits the generation of margin recommendations in relation to adjacent anatomy and quantifies interobserver variability in specified directions. This method can be applied to future consensus CTV contouring studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据