4.1 Article

On the pyrotechnic ignitors role in dust explosion testing: Comparison between 20 L and 1 m3 explosion vessels

期刊

PROCESS SAFETY PROGRESS
卷 40, 期 4, 页码 289-295

出版社

WILEY
DOI: 10.1002/prs.12249

关键词

1  m(3) vessel; CFD simulation; overdriving phenomenon; pyrotechnic ignitors effect; Siwek sphere

向作者/读者索取更多资源

This study investigated the impact of pyrotechnic ignitors on pressure trends and temperature distributions in 20 L and 1 m(3) standard test vessels, showing that igniter explosions in the 20 L vessel lead to a significant increase in pressure and a more rapid and uniform diffusion of temperature compared to the 1 m(3) vessel. The flame propagation generated by the ignitors in the 20 L vessel is relevant, resulting in overdriving phenomenon and higher deflagration index values for many organic dusts measured in the 20 L vessel compared to the 1 m(3) vessel. Additionally, CFD simulations indicate that the hot core dissipates faster in the 20 L vessel due to its higher turbulence level, making dusts controlled by particle heating more prone to combustion in the 1 m(3) vessel.
Several phenomena (e.g., initial turbulence level, overdriving, underdriving, etc.) affect the measurement of dust explosion parameters in the 20 L and 1 m(3) standard test vessels. Estimating the role of each phenomenon is crucial to understand the discrepancies observed over the years between the data collected using these vessels. In this work, we focus on the role of the pyrotechnic ignitors on the pressure trend and the temperature distribution. We run explosion tests in the 20 L vessel to measure the pressure-time history generated by the explosion of pyrotechnic ignitors. Moreover, we performed CFD simulations to simulate the spatial/temporal evolution of the temperature map from the hot core due to the igniter explosion toward the vessel walls. The explosion of the pyrotechnic ignitors shows a significant increase of pressure in the 20 L vessel, suggesting that flame propagation is occurring inside the vessel. Furthermore, the localized increase of temperature due to the ignitor explosions, diffuse, and then uniformize much more rapidly in the 20 L vessel than in the 1 m(3) vessel. The flame propagation generated by the ignitors is very relevant in the 20 L sphere leading to the overdriving phenomenon. This result justifies the fact that for many organic dusts, the deflagration index values measured in the 20 L are much higher than those measured in the 1 m(3) vessel. CFD simulations show that the hot core generated by the ignitors dissipate much faster in the 20 L vessel than in the 1 m(3) vessel, due to the higher turbulence level of the smaller vessel. Therefore, dusts whose combustion is controlled by particle heating are more prone to sustain combustion in the 1 m(3) than in the 20 L vessel.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据