4.6 Article

Vacuum ultraviolet silicon photomultipliers applied to BaF2 cross-luminescence detection for high-rate ultrafast timing applications

期刊

PHYSICS IN MEDICINE AND BIOLOGY
卷 66, 期 11, 页码 -

出版社

IOP Publishing Ltd
DOI: 10.1088/1361-6560/abf476

关键词

cross-luminescence; fast timing; BaF2; yttrium; cadmium; lanthanum doping; ultraviolet-sensitive SiPMs; FBK VUV-HD; coincidence time resolution

资金

  1. German Federal Ministry of Education and Research [05E15CHA]
  2. project CALIPSOplus from the EU Framework Programme for Research and Innovation HORIZON 2020 [730 872]
  3. ERDF [TK141, 2014-2020.4.01.15-0011]
  4. Estonian Research Council grant [PRG-629]

向作者/读者索取更多资源

Inorganic scintillators, particularly BaF2, are widely used in high-energy physics experiments and medical diagnosis due to their fast timing capabilities. Recent advancements in silicon photomultipliers (SiPMs) have led to improved photon detection efficiencies for BaF2, allowing for better coincidence time resolution (CTR). The study shows that the slow emission from BaF2 samples can be effectively suppressed, paving the way for high-rate ultrafast timing applications in medical diagnosis and HEP.
Inorganic scintillators are widely used for fast timing applications in high-energy physics (HEP) experiments, time-of-flight positron emission tomography and time tagging of soft and hard x-ray photons at advanced light sources. As the best coincidence time resolution (CTR) achievable is proportional to the square root of the scintillation decay time it is worth studying fast cross-luminescence, for example in BaF2 which has an intrinsic yield of about 1400 photons/MeV. However, emission bands in BaF2 are located in the deep-UV at 195 nm and 220 nm, which sets severe constraints on photodetector selection. Recent developments in dark matter and neutrinoless double beta decay searches have led to silicon photomultipliers (SiPMs) with photon detection efficiencies of 20%-25% at wavelengths of 200 nm. We tested state-of-the-art devices from Fondazione Bruno Kessler and measured a best CTR of 51 +/- 5 ps full width at half maximum when coupling 2 mm x 2 mm x 3 mm BaF2 crystals excited by 511 keV electron-positron annihilation gammas. Using these vacuum ultraviolet SiPMs we recorded the scintillation kinetics of samples from Epic Crystal under 511 keV excitation, confirming a fast decay time of 855 ps with 12.2% relative light yield and 805 ns with 84.0% abundance, together with a smaller rise time of 4 ps beyond the resolution of our setup. The total intrinsic light yield was determined to be 8500 photons/MeV. We also revealed a faster component with 136 ps decay time and 3.7% light yield contribution, which is extremely interesting for the fastest timing applications. Timing characteristics and CTR results on BaF2 samples from different producers and with different dopants (yttrium, cadmium and lanthanum) are given, and clearly show that the the slow 800 ns emission can be effectively suppressed. Such results ultimately pave the way for high-rate ultrafast timing applications in medical diagnosis, range monitoring in proton or heavy ion therapy and HEP.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据