4.6 Article

High-accuracy projector calibration method for fringe projection profilometry considering perspective transformation

期刊

OPTICS EXPRESS
卷 29, 期 10, 页码 15053-15066

出版社

OPTICAL SOC AMER
DOI: 10.1364/OE.424537

关键词

-

类别

资金

  1. National Key Research and Development Program of China [2017YFF0106404]
  2. National Natural Science Foundation of China [51675160, 52075147]
  3. Hebei Province Graduate Innovation Funding Project [CXZZBS2021032]

向作者/读者索取更多资源

A novel projector calibration method is proposed in this paper to improve the calibration accuracy of DLP projector by fixing the position of the camera and calibration board. Experimental results show that this method is feasible and easy to operate, effectively eliminating the perspective transformation error and ensuring competitive accuracy.
Camera and projector are the key components of structured light three-dimensional (3-D) measurements, and Digital Light Processing (DLP) projector has been widely used for projecting digital structured light patterns for the measurement. The light projecting of projectors can be modeled as the inverse procedures of camera imaging, and its high-accuracy calibration is still a remaining challenge. Therefore, this paper proposes a novel projector calibration method to improve the calibration accuracy of DLP projector. By fixing the position of the camera and calibration board, this method essentially eliminates the perspective transformation error and effectively avoids the distortion of the extracted marker points. The proposed projector calibration procedures are given as follows: Firstly, the optical axis of the camera is adjusted parallel to the normal of the hollow ring calibration board, and a texture image is captured by the camera; Secondly, the horizontal and vertical fringe patterns with nine different positions and directions are projected onto the calibration board, and nine sets of projected images are taken; Finally, a one-to-one correspondence between the camera and the projector is established, and the projector is accurately calibrated using the phase equivalence. The experimental results show that the proposed projector calibration method is feasible and easy to operate, which can essentially eliminate the perspective transformation error and ensure the competitive accuracy. (C) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据