OCT Angiography Artifacts in Glaucoma

期刊

OPHTHALMOLOGY
卷 128, 期 10, 页码 1426-1437

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.ophtha.2021.03.036

关键词

Artifact; Glaucoma; OCT angiography

资金

  1. National Institutes of Health/National Eye Institute [EY029058, EY011008, EY027510, EY026574, P30EY022589]
  2. UC Tobacco-Related Disease Research Program [T31IP1511]
  3. Research to Prevent Blindness (New York, NY)
  4. Alcon Laboratories Inc
  5. Allergan
  6. Akorn
  7. Pfizer Inc.

向作者/读者索取更多资源

The study aimed to investigate the prevalence of different types of artifacts in OCTA images and evaluate characteristics associated with poor-quality images. Older age, male gender, worse visual field mean deviation, absence of eye tracking, and macular scan area were associated with a higher likelihood of obtaining poor-quality images. The study suggests conducting systematic scan review to ensure appropriate interpretation of OCTA images due to the frequent occurrence of OCTA artifacts associated with poor-quality images.
Purpose: To determine the prevalence of different types of artifacts seen in OCT angiography (OCTA) images of healthy and glaucoma eyes and evaluate the characteristics associated with poor-quality images. Design: Retrospective study. Participants: A total of 649 eyes of 368 healthy, glaucoma suspect, and glaucoma patients. Methods: Angiovue (Optovue Inc) high-density (HD) and non-HD optic nerve head and macula OCTA images of participants were evaluated by 4 expert reviewers for the presence of different artifacts, including eye movement, defocus, shadow, decentration, segmentation error, blink, and Z offset in the superficial vascular layer. Each OCTA scan was designated to have good or poor quality based on the presence of artifacts. The association of demographic and ocular characteristics with the likelihood of obtaining poor-quality OCTA images was evaluated. Main Outcome Measures: The prevalence of OCTA artifacts and the factors associated with increased likelihood of capturing poor-quality OCTA images. Results: A total of 5263 OCTA images were evaluated. Overall, 33.9% of the OCTA images had poor quality. The majority of images with acceptable quality scores (QS >= 4) had no artifacts (76.6%). Other images had 1 (13.6%) or 2 or more artifacts (9.8%). Older age (P < 0.001), male gender (P = 0.045), worse visual field mean deviation (P < 0.001), absence of eye tracking (P < 0.001), and macular scan area (P < 0.001) were associated with a higher likelihood of obtaining poor-quality images. In images with acceptable QS, the commercially available quality measures including QS and signal strength index had the area under the receiver operating characteristic curves of 0.65 (95% confidence interval [CI], 0.62-0.69) and 0.70 (95% CI, 0.68-0.73) to detect good-quality images, respectively. Conclusions: OCTA artifacts associated with poor-quality images are frequent, and their prevalence is affected by ocular and patient characteristics. One should not rely solely on the quantitative assessments that are provided automatically by OCTA instruments. A systematic scan review should be conducted to ensure appropriate interpretation of OCTA images. Given the high prevalence of poor-quality OCTA images, the images should be reacquired whenever an apparent and correctable artifact is present on a captured image. (C) 2021 by the American Academy of Ophthalmology

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据