4.6 Article

A Label-Free Fluorometric Glutathione Assay Based on a Conformational Switch of G-quadruplex

期刊

MOLECULES
卷 26, 期 9, 页码 -

出版社

MDPI
DOI: 10.3390/molecules26092743

关键词

glutathione; G-quadruplex; mercury ions; thioflavin T; fluorescence assay

资金

  1. National Natural Science Foundation of China [21205142]
  2. Research Innovation Program for Graduates of Central South University [2018zzts384, 2019zzts453]

向作者/读者索取更多资源

A label-free fluorescent method for detecting glutathione (GSH) based on a thioflavin T/G-quadruplex conformational switch is developed, showing high sensitivity and selectivity. The method can also be applied to detect other amino acids with satisfactory efficacy.
In this paper, a label-free fluorescent method for glutathione (GSH) detection based on a thioflavin T/G-quadruplex conformational switch is developed. The sensing assay is fabricated depending on the virtue of mercury ions to form a thymine-thymine mismatch, which collapses the distance between two ssDNA and directs the guanine-rich part to form an intra-strand asymmetric split G-quadruplex. The newly formed G-quadruplex efficiently reacts with thioflavin T and enhances the fluorescent intensity. In the presence of GSH, Hg2+ is absorbed, destroying the G-quadruplex formation with a significant decrease in fluorescence emission. The proposed fluorescent assay exhibits a linear range between 0.03-5 mu M of GSH with a detection limit of 9.8 nM. Furthermore, the efficacy of this method is examined using human serum samples to detect GSH. Besides GSH, other amino acids are also investigated in standard samples, which display satisfactory sensitivity and selectivity. Above all, we develop a method with features including potentiality, facility, sensitivity, and selectivity for analyzing GSH for clinical diagnostics.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论