4.5 Review

Comparative efficacy and safety of intravenous ferric carboxymaltose and iron sucrose for iron deficiency anemia in obstetric and gynecologic patients A systematic review and meta-analysis

期刊

MEDICINE
卷 100, 期 20, 页码 -

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MD.0000000000024571

关键词

ferric carboxymaltose; gynecologic; iron deficiency anemia; iron sucrose; obstetric

向作者/读者索取更多资源

This systematic review compared the efficacy and safety of ferric carboxymaltose (FCM) and iron sucrose (IS) in treating iron deficiency anemia (IDA) in obstetric and gynecologic patients. The results showed that FCM was more effective in increasing Hb and ferritin levels compared to IS, with a more favorable safety profile.
Introduction: Iron deficiency anemia (IDA) is common among obstetric and gynecologic patients. This systematic review aimed to assess the comparative efficacy and safety of commonly used intravenous (IV) iron formulations, ferric carboxymaltose (FCM), and iron sucrose (IS) in the treatment of IDA in obstetric and gynecologic patients. Methods: We systematically searched PubMed, EMBASE, Cochrane CENTRAL, and Google Scholar for eligible randomized controlled trials (RCTs) comparing IV iron replacement using FCM and IS up to October 2019. The primary outcome was to compare the efficacy of FCM and IS, assessed by measuring serum hemoglobin (Hb) and ferritin levels before and after iron replacement. The secondary outcome was to compare the safety of FCM and IS, assessed by the incidence of adverse events during iron replacement. The meta-analysis was performed using RevMan 5.3. Results: We identified 9 RCTs with 910 patients (FCM group, n = 456; IS group, n = 454). Before iron replacement, FCM and IS group patients had similar baseline Hb (mean difference [MD], 0.04 g/dL; 95% confidence interval [CI], -0.07 to 015; I-2 = 0%; P = 0.48) and ferritin levels (MD, -0.42 ng/mL; 95% CI, -1.61 to 0.78; I-2 = 45%; P = 0.49). Following iron replacement, patients who received FCM had higher Hb (MD, 0.67; 95% CI, 0.25-1.08; I-2 = 92%; P = 0.002) and ferritin levels (MD, 24.41; 95% CI, 12.06-36.76; I-2 = 75%; P = 0.0001) than patients who received IS. FCM group showed a lower incidence of adverse events following iron replacement than IS group (risk ratio, 0.53; 95% CI, 0.35-0.80; I-2 = 0%; P = 0.003). Serious adverse events were not reported in any group. Conclusion: FCM group showed better efficacy in increasing Hb and ferritin levels and a favorable safety profile with fewer adverse events compared with IS group for IDA treatment among obstetric and gynecologic patients. However, this meta-analysis was limited by the small number of RCTs and high heterogeneity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据