4.4 Article

The efficacy of Raman spectroscopy in lung cancer diagnosis: the first diagnostic meta-analysis

期刊

LASERS IN MEDICAL SCIENCE
卷 37, 期 1, 页码 425-434

出版社

SPRINGER LONDON LTD
DOI: 10.1007/s10103-021-03275-4

关键词

Lung cancer; Raman spectroscopy; Diagnostic performance; Meta-analysis

资金

  1. Anhui University Natural Science Research Project [KJ2018A0208]

向作者/读者索取更多资源

The study found through meta-analysis that Raman spectroscopy has high sensitivity and specificity in diagnosing lung cancer, making it a promising diagnostic technology. Analysis of different sample types showed variations in diagnostic performance, indicating the need for further research in this area.
In recent years, many researches have explored the diagnostic value of Raman spectroscopy in multiple types of tumors. However, as an emerging clinical examination method, the diagnostic performance of Raman spectroscopy in lung cancer remains unclear. Relevant diagnostic studies published before 1 June 2020 were retrieved from the Cochrane Library, PubMed, EMBASE, China National Knowledge Internet (CNKI), and WanFang databases. After the literature was screened, two authors extracted the data from eligible studies according to the inclusion and exclusion criteria. Obtained data were pooled and analyzed using Stata 16.0, Meta-DiSc 1.4, and RevMan 5.3 software. Fourteen diagnostic studies were eligible for the pooled analysis which includes 779 patients. Total pooled sensitivity and specificity of Raman spectroscopy in diagnosing lung cancer were 0.92 (95% CI 0.87-0.95) and 0.94 (95% CI 0.88-0.97), respectively. The positive likelihood ratio was 15.2 (95% CI 7.5-30.9), the negative likelihood ratio was 0.09 (95% CI 0.05-0.14), and the area under the curve was 0.97 (95 % CI 0.95-0.98). Subgroup analysis suggested that the sensitivity and specificity of RS when analyzing human tissue, serum, and saliva samples were 0.95 (95% CI 0.88-0.98), 0.97 (95% CI 0.89-0.99), 0.88 (95% CI 0.80-0.93), 0.87 (95% CI 0.78-0.92), 0.91 (95% CI 0.80-0.96), and 0.95 (95% CI 0.73-0.99), respectively. No publication bias or threshold effects were detected in this meta-analysis. This initial meta-analysis indicated that Raman spectroscopy is a highly specific and sensitive diagnostic technology for detecting lung cancer. Further investigations are also needed to focus on real-time detection using Raman spectroscopy under bronchoscopy in vivo. Moreover, large-scale diagnostic studies should be conducted to confirm this conclusion.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据