Heart rate detection by Fitbit ChargeHR™: A validation study versus portable polysomnography

期刊

JOURNAL OF SLEEP RESEARCH
卷 30, 期 6, 页码 -

出版社

WILEY
DOI: 10.1111/jsr.13346

关键词

electrocardiography; photoplethysmography; wearables

资金

  1. School of Medicine University of Pisa
  2. ARPA Foundation (Pisa, Italy)

向作者/读者索取更多资源

The study investigated the reliability of pulse photoplethysmographic detection by Fitbit ChargeHR in a natural setting. Results showed that FBCHR had higher accuracy in estimating HR during sleep and lower correlation during wakefulness, with even lower correlation for HRs >100 bpm. Therefore, FBCHR is suitable for sleep-related research in healthy individuals under free-living conditions.
Consumer Smartbands can collect physiological parameters, such as heart rate (HR), continuously across the sleep-wake cycle. Nevertheless, the quality of HR data detected by such devices and their place in the research and clinical field is debatable, as they are rarely rigorously validated. The objective of the present study was to investigate the reliability of pulse photoplethysmographic detection by the Fitbit ChargeHR((TM)) (FBCHR, Fitbit Inc.) in a natural setting of continuous recording across vigilance states. To fulfil this aim, concurrent portable polysomnographic (pPSG) and the Fitbit's photoplethysmographic data were collected from a group of 25 healthy young adults, for >= 12 hr. The pPSG-derived HR was automatically computed and visually verified for each 1-min epoch, while the FBCHR HR measurements were downloaded from the application programming interface provided by the manufacturer. The FBCHR was generally accurate in estimating the HR, with a mean (SD) difference of -0.66 (0.04) beats/min (bpm) versus the pPSG-derived HR reference, and an overall Pearson's correlation coefficient (r) of 0.93 (average per participant r = 0.85 +/- 0.11), regardless of vigilance state. The correlation coefficients were larger during all sleep phases (rapid eye movement, r = 0.9662; N1, r = 0.9918; N2, r = 0.9793; N3, r = 0.9849) than in wakefulness (r = 0.8432). Moreover, the correlation coefficient was lower for HRs of >100 bpm (r = 0.374) than for HRs of <100 bpm (r = 0.84). Consistently, Bland-Altman analysis supports the overall higher accuracy in the detection of HR during sleep. The relatively high accuracy of FBCHR pulse rate detection during sleep makes this device suitable for sleep-related research applications in healthy participants, under free-living conditions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据