4.5 Article

Development of hydrophilic magnetic molecularly imprinted polymers for the dispersive solid-phase extraction of sulfonamides from animal-derived samples before HPLC detection

期刊

JOURNAL OF SEPARATION SCIENCE
卷 44, 期 12, 页码 2399-2407

出版社

WILEY-V C H VERLAG GMBH
DOI: 10.1002/jssc.202001244

关键词

dispersive solid‐ phase extraction; high‐ performance liquid chromatography; hydrophilic polymers; magnetic molecularly imprinted polymers; sulfonamides

资金

  1. Department of Science & Technology of Shandong Province, China [2018GNC110029]
  2. Beijing Laboratory of Food Quality and Safety, Beijing Technology and Business University [FQS-201805]
  3. Open Project Program of State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science Technology [SKLFNS-KF201805]

向作者/读者索取更多资源

Highly hydrophilic magnetic molecularly imprinted polymers were prepared for the detection of trace levels of sulfonamides in animal-derived samples, showing excellent specific adsorption properties for the target template compound. The method, with good linear performance and high recoveries in spiked samples, avoids the use of organic solvents and simplifies the pretreatment process. This approach holds great potential for rapid detection of drug residues.
Highly hydrophilic magnetic molecularly imprinted polymers were prepared through a surface imprinting technique for dispersive solid-phase extraction coupled with high-performance liquid chromatography to detect trace levels of ten sulfonamides in animal-derived samples. The obtained imprinted polymers were characterized by Fourier transform infrared spectroscopy, scanning electron microscopy, thermogravimetric analysis, and adsorption experiments, which exhibited excellent specific adsorption for template sulfamethazine in aqueous solution. Moreover, the adsorption process could be completed within 25 min. Under the optimum conditions, the method exhibits good linear performance in the range of 5-to 10 mg/L, limits of detection ranging from 0.57 to 1.50 mu g/L, and good recoveries of 85.09-110.93% in the spiked samples (chicken, cow milk, and goat milk). The proposed detection method not only avoids the use of organic solvents but also simplifies the pretreatment procedure via excellent magnetic properties. Furthermore, the method shows great potential for the rapid detection of drug residues.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据