期刊
JOURNAL OF INSTRUMENTATION
卷 16, 期 5, 页码 -出版社
IOP PUBLISHING LTD
DOI: 10.1088/1748-0221/16/05/P05008
关键词
Calorimeters; Cherenkov detectors; Heavy-ion detectors
资金
- Office of Science, US Department of Energy
- New National Excellence Program of the Ministry for Innovation and Technology [UNKP-19-3]
- National Research, Development and Innovation Office of Hungary [K 124845, K 128713, K 128786, FK 123842]
- Hungarian Academy of Sciences Lendulet (Momentum) Program [LP 2015-7/2015]
This paper investigates the performance of the CMS experiment's ZDC in the 2016 pPb run, studying the detectors' response to ultrarelativistic neutrons using in-depth Monte Carlo simulations. It presents a method of signal extraction based on template fits and a dedicated calibration procedure, as well as discusses a deconvolution technique for correcting overlapping collision events.
The two Zero Degree Calorimeters (ZDCs) of the CMS experiment are located at +/- 140m from the collision point and detect neutral particles in the |eta | > 8 .3 pseudorapidity region. This paper presents a study on the performance of the ZDC in the 2016 pPb run. The response of the detectors to ultrarelativistic neutrons is studied using in-depth Monte Carlo simulations. A method of signal extraction based on template fits is presented, along with a dedicated calibration procedure. A deconvolution technique for the correction of overlapping collision events is discussed.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据