Concrete Columns Reinforced with GFRP and BFRP Bars under Concentric and Eccentric Loads: Experimental Testing and Analytical Investigation

期刊

出版社

ASCE-AMER SOC CIVIL ENGINEERS
DOI: 10.1061/(ASCE)CC.1943-5614.0001115

关键词

Concrete columns; Concentric loading; Eccentric loading; Fiber-reinforced polymer; Basalt; BFRP; GFRP; Interaction diagrams

资金

  1. American University of Sharjah [IRF-002]

向作者/读者索取更多资源

The study tested twelve concrete columns reinforced with FRP bars under concentric and eccentric loadings, finding that columns reinforced with BFRP and GFRP had similar load-carrying capacities, lower than their steel-reinforced counterparts, with a more pronounced impact of increasing reinforcement ratio on eccentric columns. The contribution of GFRP and BFRP bars to column capacity was similar, while ignoring the strength contribution of FRP bars in design codes may lead to conservative predictions.
Twelve concrete columns reinforced longitudinally with fiber-reinforced polymer (FRP) bars were tested under both concentric and eccentric loadings. The investigated parameters were the type of the FRP bar, the longitudinal reinforcement ratio, and the load eccentricity-to-width ratio. The test results showed that the columns reinforced with basalt-FRP (BFRP) and glass-FRP (GFRP) experienced similar load-carrying capacity with a difference of less than 5%. Both types of columns attained lower ultimate capacity than their steel-reinforced counterparts. The contribution of the GFRP and BFRP bars to the ultimate capacity of the columns was similar, approximately 11% of the capacity, as compared to 31% for the steel bars. The effect of increasing the reinforcement ratio on the capacity was more pronounced in the eccentric FRP-reinforced concrete (FRP-RC) columns than the concentric ones. The analytical investigation showed that ignoring the strength contribution of the FRP bars, as recommended by most of the current codes and design guidelines, would result in conservative predictions. It also showed that current Canadian design code recommendation limiting the strains in FRP bars in compression to 2,000 mu e yielded reasonable predictions of the column capacity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据