4.7 Article

Mitigating damage on heritage structures by continuous conservation using thermal real-time monitoring. Case study of Ziri Wall, city of Granada, Spain

期刊

JOURNAL OF CLEANER PRODUCTION
卷 296, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jclepro.2021.126522

关键词

Heritage buildings; Impact of climate; Preventive conservation; Inverse model; Historic preservation

资金

  1. State Research Agency of Spain
  2. European Regional Development Fund (ERDF) [BIA2015 69938-R, A_B.4.3_0218]

向作者/读者索取更多资源

The study presents a method to automatically diagnose heritage building elements using standard monitoring, with potential applications in the field of environmental monitoring.
Climate change and anthropogenic causes represent a multidisciplinary problem in urban environments, specifically in the destruction of historical elements of enormous value. Although conventional preser-vation methods are based on comprehensive conservation measures and periodic inspection, these ur-ban elements sometimes lie in a state of neglect due to lack of means to carry out continuous monitoring. The present work develops a replicable and easy-to-apply multi-analytical methodology, which proposes the use of standard monitoring to automatically diagnose the elements of heritage buildings. Similar approaches are becoming popular in the setting of Structural Health Monitoring, and their application in the field of environmental monitoring is one of the valuable outputs of this work. Diagnosis is based on the development of an inverse characterisation model of the thermal response in a known state of conservation through standard monitoring. This model is calibrated using real measurements. The methodology involves characterising energy response to environmental excitations measured against what is deemed to be a baseline state of conservation. Also, the monitoring system and data processing required is defined and explained in detail. Anomalies detected in the comparison of the baseline to subsequent real-time measurements would highlight the need to bring scheduled on-site inspections forward with an affordable cost. This benchmarking using the estimation of baseline and real mea-surements is the main result of the methodology. Finally, the methodology developed was validated with an exhaustive study conducted on the Ziri Wall at Granada, Spain, in both summer and winter. The findings revealed a good fit between calculated and experimental data, with mean absolute errors of under 1 degrees C in both seasons. The proposal can be applied in other fields such as preventive maintenance. (c) 2021 Elsevier Ltd. All rights reserved. Superscript/Subscript Available

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据