4.6 Article

Characterisation of selenium and tellurium nanoparticles produced by Aureobasidium pullulans using a multi-method approach

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1642, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2021.462022

关键词

Biogenic nanoparticles; Selenium; Tellurium; AF4; ICP-MS/MS; spICP-MS

资金

  1. University of Aberdeen's Elphinstone PhD studentship award [RG13451]
  2. Niger-Delta Development Commission (NDDC) Postgraduate Foreign Scholarship [NDDC/DEHSS/2015PGFS/IMS/09]
  3. Natural Environment Research Council under the NERC Security of Supply of Mineral Resources Grant Programme: Tellurium and Selenium cycling and supply (TeaSe) [NE/M010910/1]

向作者/读者索取更多资源

The study recovered and characterized selenium (Se) and tellurium (Te) nanoparticles (NPs) using asymmetric flow field flow fractionation (AF4) coupled with various detectors. Different buffer solutions and flow rates were compared for optimal separation and recovery of NPs, with Novachem solution showing higher stability for elution. The results demonstrate the effectiveness of complementary techniques in characterizing biogenic Se and Te NPs.
Aureobasidium pullulans was grown in liquid culture media amended with selenite and tellurite and selenium (Se) and tellurium (Te) nanoparticles (NPs) were recovered after 30 d incubation. A separation method was applied to recover and characterise Se and Te NPs by asymmetric flow field flow fractionation (AF4) with online coupling to multi-angle light scattering (MALS), ultraviolet visible spectroscopy (UV-Vis), and inductively coupled plasma mass spectrometry (ICP-MS) detectors. Additional characterisation data was obtained from transmission electron microscopy (TEM), and dynamic light scattering (DLS). Solutions of 0.2% Novachem surfactant and 10 mM phosphate buffer were compared as mobile phases to investigate optimal AF4 separation and particle recovery using Se-NP as a model sample. 88% recovery was reported for 0.2% Novachem solution, compared with 50% recovery for phosphate buffer. Different crossflow (C-flow) rates were compared to further investigate optimum separation, with recoveries of 88% and 30% for Se-NPs, and 90% and 29% for Te-NPs for 3.5 mL min(-1) and 2.5 mL min(-1) respectively. Zeta-potential (ZP) data suggested higher stability for NP elution in Novachem solution, with increased stability attributed to minimised NP-membrane interaction due to PEGylation. Detection with MALS showed monodisperse Se-NPs (45-90 nm) and polydisperse Te-NPs (5-65 nm).Single particle ICP-MS showed mean particle diameters of 49.7 +/- 2.7 nm, and 135 +/- 4.3 nm, and limit of size detection (LOSD) of 20 nm and 45 nm for Se-NPs and Te-NPs respectively. TEM images of Se-NPs and Te-NPs displayed a spherical morphology, with the Te-NPs showing a clustered arrangement, which suggested electrostatic attraction amongst neighbouring particles. Particle hydrodynamic diameters (d(H)) measured with dynamic light scattering (DLS) further suggested monodisperse Se-NPs and polydisperse Te-NPs distributions, showing good agreement with AF4-MALS for Se-NPs, but suggests that the R-g obtained from AF4-MALS for Te-NP was unreliable. The results demonstrate a complementary application of asymmetric flow field-flow fractionation (AF4), ICP-MS, light scattering, UV-Vis detection, and microscopic techniques to characterise biogenic Se and Te NPs. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据