4.6 Article

Simultaneous determination of three endogenous chiral thiol compounds in serum from humans at normal and stress states using ultrahigh-performance liquid chromatography coupled to quadrupole-Orbitrap high resolution mass spectrometry

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1642, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2021.462028

关键词

Chiral thiol compound; NCS-OTPP; Diastereomeric separation; Oxidative stress, UHPLC-Q-Orbitrap HRMS

资金

  1. National Natural Science Foundation of China [81660594]
  2. Science and Technology Development Project, Education Department of Jilin Province of China [JJKH20191151KJ]

向作者/读者索取更多资源

A novel chiral mass spectrometry derivatization reagent and method were developed for simultaneous determination of three kinds of chiral thiol compounds, showing excellent linearity, suitable precision, and satisfactory accuracy.
Measurement of chiral thiol compounds such as glutathione (GSH), cysteine (Cys), and homocysteine (Hcy) in human serum plays an important role in the early diagnosis and warning of cardiovascular disease, neurodegenerative disease, and cancer. We developed a novel chiral mass spectrometry derivatization reagent, (R)-(5-(3-isothiocyanatopyrrolidin-1-yl)-5-oxopentyl) triphenylphosphonium (NCS-OTPP), with triphenylphosphine (TPP) as a basic structure carrying a permanent positive charge for the diastere-omeric separation of chiral thiol compounds by ultrahigh-performance liquid chromatography coupled to quadrupole-Orbitrap high resolution mass spectrometry (UHPLC-Q-Orbitrap HRMS). A novel method was developed for simultaneous determination of three kinds of chiral thiol compounds based on the NCS-OTPP derivatization method. Three kinds of chiral thiol compounds on a YMC Triart C18 (2.0 x 150 mm, 1.9 mu m) column with Rs were 1.56-1.68. The protonated precursor to product ion transitions monitored for GSH was m/z 780.16 -> 747.24/473.18, Cys was m/z 594.20 -> 561.18/473.18, and Hcy was m/z 608.21 -> 575.19/473.18. An excellent linearity for all the analytes with correlation coefficients >= 0.9995 and suitable precision with inter-day and intra-day coefficients of variation RSDs was 0.83-4.06% and 0.95-3.11%. Satisfactory accuracy with recoveries between 83.73 and 103.35% was observed. The limit of detection (S/N = 3) was 2.4-7.2 fmol. Furthermore, the method was successfully applied to the simultaneous determination of three kinds of free and total thiol compounds in serum from 10 healthy volunteers at normal and stress states. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据