4.6 Article

Ultrasound-assisted magnetic solid-phase extraction of polycyclic aromatic hydrocarbons and nitrated polycyclic aromatic hydrocarbons from water samples with a magnetic polyaniline modified graphene oxide nanocomposite

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1645, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.chroma.2021.462104

关键词

Magnetic solid phase extraction; Polycyclic aromatic hydrocarbons; Nitrated polycyclic aromatic hydrocarbons; Graphene oxide; Water samples

资金

  1. Hellenic Foundation for Research and Innovation (HFRI) [138]

向作者/读者索取更多资源

A novel magnetic Fe3O4@GO-PANI nanocomposite was synthesized and applied for the magnetic solid-phase extraction of PAHs and N-PAHs with high accuracy, low limits of detection, and good stability. The method was successfully applied to water samples from various sources, and the sorbent could be reused multiple times, demonstrating practical value.
A novel magnetic graphene oxide nanocomposite modified with polyaniline (Fe3O4@GO-PANI) was synthesized and applied for the magnetic solid-phase extraction of polycyclic aromatic hydrocarbons (PAHs) (i.e. fluorene, phenanthrene and pyrene) and nitrated polycyclic aromatic hydrocarbons (N-PAHs) (i.e. 2-nitrofluorene, 9-nitroanthracene, 1-nitropyrene and 3-nitrofluoranthene) prior to their determination by gas chromatography-mass spectrometry. The prepared nanomaterial was characterized by scanning electron microscopy, X-ray diffraction, and Fourier transform-infrared spectroscopy. The main experimental parameters affecting the extraction and desorption steps of the MSPE procedure were investigated and optimized. Under optimum conditions, coefficients of determination (r(2)) ranged between 0.9970 and 0.9995, limits of detection (LODs, S/N = 3) ranged between 0.04-0.05 ng mL(-1) for PAHs and 0.01-0.11 ng mL(-1) for N-PAHs, while the relative standard deviation for intra-day and inter-day repeatability were lower than 10.0% for PAHs and N-PAHs. The method was successfully applied to the analysis of tap, mineral and river water samples. Relative recoveries in spiked water samples ranged between from 91.6 to 114% and from 92.3 to 110% for PAHs and N-PAHs, respectively. The proposed method is simple, rapid, sensitive and the Fe3O4@GO-PANI sorbent can be reused for at least 15 times without significant decrease in extraction recovery. (C) 2021 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据