4.3 Article

Organization and procedures in contemporary catheter ablation centres: data from the 2018 Italian Catheter Ablation Registry

期刊

JOURNAL OF CARDIOVASCULAR MEDICINE
卷 22, 期 8, 页码 631-636

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.2459/JCM.0000000000001183

关键词

arrhythmias; catheter ablation; registry

向作者/读者索取更多资源

The 2018 Italian Catheter Ablation Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) collected data on 15,714 catheter ablation procedures performed in 94 electrophysiology centres in Italy. The findings showed that most centres had a single electrophysiology laboratory and at least two electrophysiologists involved in the procedures, with an increasing use of nonfluoroscopic mapping systems and near-zero approach.
Aims This report describes the findings of the 2018 Italian Catheter Ablation Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC). Methods The Italian Catheter Ablation Registry systematically collects data on the ablation procedures performed in Italy. Data collection was retrospective. A standardized questionnaire was completed by participating centres. Results We collected data on 15 714 catheter ablation procedures performed in Italy during 2018 in 94 electrophysiology centres. In most centres (75/94, 80%), a single electrophysiology laboratory was available, and a hybrid electrophysiology laboratory was available in 15% (14/94) of centres. In most (93%) centres, at least two electrophysiologists were involved in the catheter ablation procedures. In only 13 out of 94 (14%) electrophysiology laboratories, an anaesthesiologist assists every electrophysiology procedure; in most cases (74/94, 79%), an on-demand anaesthesiology service was available. On-site cardiothoracic surgery was reported in 43 out of 94 (46%) centres. Nonfluoroscopic navigation systems were available in most centres (88/94, 93%). Intracardiac echocardiography was used in 59 out of 94 (63%) electrophysiology laboratories. Atrial fibrillation (31%) was the most frequently treated ablation target, followed by atrioventricular nodal re-entrant tachycardia (20%) and cavo-tricuspid isthmus (15%). In 61.7% of all procedures, a 3D mapping system was used. In about one-third of procedures, a near-zero approach was performed. Conclusion In most Italian electrophysiology centres, a single electrophysiology laboratory was available and at least two electrophysiologists were involved in the ablation procedures. An increasing number of procedures were performed by means of a nonfluoroscopic mapping system with a near-zero approach.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据