Aortic root haemodynamics following David procedure: numerical analysis of 3-dimensional haemodynamics

期刊

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
卷 49, 期 6, 页码 1588-1598

出版社

OXFORD UNIV PRESS INC
DOI: 10.1093/ejcts/ezv427

关键词

Aortic root; Aortic root sparing procedure; Haemodynamics; Aortic root aneurysm

向作者/读者索取更多资源

The aim was to determine 3-dimensional (3D) geometrical deformation of the aortic root (AoR) following the David procedure in order to evaluate local haemodynamical conditions of individual AoR elements. In the experimental set-up, the David procedure was performed on 10 domestic pigs. Data were compared with the measurements obtained in 10 native AoRs. In each AoR, six high-resolution ultrasonometric crystals (200 Hz) were implanted, being positioned at each commissure and at the AoR base. 3D geometrical deformation of the AoR, torsion and tilt angle was determined. Computed fluid dynamics (CFD) simulation analysis was used to evaluate local pressure, flow and shear stress. In David AoRs, the tilt angle was maximal at a peak ejection of 25.9 +/- 1.49A degrees and minimal at the end of isovolemic contraction at 23.5 +/- 0.80A degrees. David root rotation was maximal at a peak ejection of 27.93 +/- 1.54A degrees and minimal at the end of the isovolemic contraction at 25.7 +/- 1.32A degrees. In the native AoR, the opposite was observed. Here, the tilt and rotation angle were maximal at the end of isovolemic contraction (17.25 +/- 0.68A degrees and 19.71 +/- 0.73A degrees) and decreased to its minimal values at peak ejections (14.1 +/- 0.62A degrees and 16.33 +/- 0.47A degrees). In David AoR, high pressure (> 140 mmHg) combined with low-to-moderate shear stress (0-40 Pa) was found at the leaflet body from the beginning of isovolemic contraction till the opening of the aortic valve. Similar high pressure (> 140 mmHg) and shear stress (0-40 Pa) were found in the period from aortic valve closure till the beginning of the isovolemic contraction. In native AoRs, high pressure (> 95 mmHg) was conjoined with low-to-moderate shear stress (0-30 Pa) at the leaflets and was registered at the end of isovolemic contraction. The David AoR is haemodynamically less favourable when compared with the native AoR. During almost two-thirds of the time period of the cardiac cycle, AoR elements are exposed to high pressure and low shear stress. In contrast, in native AoRs, similar conditions were present only during the short period of isovolemic contraction.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据