4.6 Article

Off-pump mitral valved stent implantation: comparison of apical and subannular fixation techniques

期刊

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
卷 51, 期 1, 页码 112-118

出版社

OXFORD UNIV PRESS INC
DOI: 10.1093/ejcts/ezw223

关键词

Off-pump; Transapical; Mitral valved stent; Stent design; Transcatheter; Fixation techniques

资金

  1. German Research Foundation, Bonn, Germany [LU 663/8-1]
  2. German Centre for Cardiovascular Research (DZHK)

向作者/读者索取更多资源

OBJECTIVES: A large cohort of patients suffering from severe mitral regurgitation does not meet the indications for conventional surgery and would greatly benefit from a transcatheter approach in the beating heart. Consequently, off-pump transcatheter mitral valve procedures have been the focus of recent research. The aim of this study was the in vivo evaluation and comparison of subannular versus apical fixation of mitral valved stents to show the feasibility of subannular anchorage. METHODS: Twenty-two pigs received a self-expanding valved stent in the mitral position in an off-pump procedure. The first design (design AP: n = 12) was anchored apically and served as the control group. The second design (design SA: n = 10) included additional subannular fixation elements. Echocardiographic and haemodynamic evaluations were conducted before and 1 h after stent implantation. RESULTS: Haemodynamic stability was achieved, and the capillary wedge pressure was within a normal range (AP: 11 +/- 4 mmHg, SA: 9 +/- 4 mmHg). Paravalvular leakages were trace or less in 19 of 20 cases. The mean gradients across the valved stent increased (P = 0.014) but remained within a physiological range in both groups (AP: 1.2 +/- 0.6 mmHg, SA: 2.6 +/- 2.0 mmHg). The longitudinal heart function remained within a physiological normal range (AP: 0.95 +/- 0.1 cm, SA: 0.95 +/- 0.1 cm) but was reduced in group SA. The ejection fraction decreased after stent implantation (AP: 52 +/- 10%, SA: 48 +/- 4%). The mean survival time was higher in group AP compared with group SA. CONCLUSIONS: The proof-of-principle for the subannular fixation was shown with haemodynamic stability, low gradients and physiological longitudinal function. A decreased ejection fraction, survival time and fractures identify potential areas for improvement. With regard to the long-term outcome, the group with subannular fixation did not reach the results of the group with apical fixation in this study.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据