4.7 Article

Numerical study of high temperature proton exchange membrane fuel cell (HT-PEMFC) with a focus on rib design

期刊

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
卷 46, 期 40, 页码 21098-21111

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2021.03.192

关键词

HT-PEMFC; Channel to rib width ratio; Reactants distribution; Thermal behavior

资金

  1. Research Grant Council, University Grants Committee, Hong Kong SAR [PolyU 152214/17E, PolyU 152064/18E]

向作者/读者索取更多资源

The rib size is a critical factor affecting the performance of high temperature proton exchange membrane fuel cells, with an optimal channel to rib width ratio of 1 leading to peak power density. The ratio value significantly influences gas diffusion, electron conduction, and current density distribution, impacting electrochemical behavior.
The rib size is a critical engineering design parameter for high temperature proton exchange membrane fuel cell (HT-PEMFC) stack development, yet it hasn't been studied for HT-PEMFC. A three-dimensional, non-isothermal model was developed in this work to investigate the effect of channel to rib width ratios (CRWR) on the performance of HT-PEMFC. The reaction heat caused by entropy change was divided into cathodic half-reaction heat and anodic half-reaction heat. The results show that the ratio value significantly influence the gas diffusion, electron conduction and the distribution of current density in the porous electrodes. Increasing this ratio facilitates gas transport in the porous electrode but causes higher ohmic loss due to longer distance for electron conduction. As a result, an optimal ratio of about 1 is observed, which results in a peak power density of 0.428 W/cm(2). High current density is observed under the channel with a small ratio value while a high ratio value would cause high current density to appear under the rib, signifying the rib size effect on electrochemical behavior of HT-PEMFC. Apart from the electrical power output, the CRWR value also greatly influences the fluid flow and temperature distribution inside the cell, which would influence the long-term stability of HT-PEMFC. In the subsequent studies, efforts will be made to develop new stack configurations with more uniform gas distribution, short electron conduction path and low temperature gradient. (C) 2021 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。