4.5 Article

Design, metallurgical features, mechanical performance and canal preparation of six reciprocating instruments

期刊

INTERNATIONAL ENDODONTIC JOURNAL
卷 54, 期 9, 页码 1623-1637

出版社

WILEY
DOI: 10.1111/iej.13529

关键词

bending load; cyclic fatigue; differential scanning calorimetry; micro‐ CT; reciprocation; torsional strength

资金

  1. FCT-Fundacao para a Ciencia e a Tecnologia, I.P. [UIDB/50025/2020-2023]

向作者/读者索取更多资源

This study compared six reciprocating instruments in terms of their geometric design, metallurgical characteristics, mechanical behavior, and ability to prepare root canals. While the instruments had similarities in metal composition and unprepared canal area, they showed differences in phase transformation temperatures and geometric design. The study found that there were variations in the overall geometric design, phase transformation temperatures, and mechanical resistance parameters among the instruments.
Aim To compare six reciprocating instruments regarding their geometric design, metallurgical characteristics, mechanical behaviour and ability to prepare root canals. Methodology A total of 246 new 25-mm NiTi instruments (41 per group) from six reciprocating systems (Reciproc, Reciproc Blue, One Files, One Files Blue, Reverso Silver, and WaveOne Gold) were evaluated throughout a multimethod approach regarding their design using stereomicroscopy (number of blades and helix angle) and scanning electron microscopy (blades symmetry, cross section and surface finishing), nickel-titanium composition, phase transformation temperatures, mechanical performance (cyclic fatigue, torsional and bending resistance) and unprepared canal surface area on anatomically matched mandibular molars assessed by micro-CT. One-way ANOVA and post hoc Tukey's or Mood's median tests were selected depending on sample distribution with significance level set at 5%. Results The instruments had similarities regarding their metal composition and unprepared canal area, whilst differences in phase transformation temperatures and geometric design (number of blades, surface finishing and tip geometry) were observed. Overall, no difference was observed regarding the maximum torque values (P > 0.05), whilst One Files (72 s) and One Files Blue (414 s) had the shortest and longest times to fracture, respectively (P < 0.05). Similar angles of rotation were observed in Reciproc (310 degrees), One Files (285 degrees) and Reverso Silver (318 degrees) instruments (P > 0.05), which were significantly lower than Reciproc Blue (492 degrees), One Files Blue (456 degrees) and WaveOne Gold (492 degrees; P < 0.05). Maximum bending load demonstrated that Reciproc Blue (201.3 gf) was significantly more flexible that the other instruments (P < 0.05). Conclusion Although there were similarities in metal composition and percentage of unprepared canal surface, the instruments had differences in the overall geometric design, phase transformation temperatures and in the four mechanical resistance parameters (time to fracture, maximum torque, angle of rotation and maximum bending load).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据