期刊
IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING
卷 16, 期 6, 页码 822-826出版社
WILEY
DOI: 10.1002/tee.23376
关键词
fault location; cable; characteristic impedance; electrical insulation; preventive maintenance
The experimental examination of the spatial resolution of a cable fault location method using frequency domain reflectometry demonstrated the method's ability to accurately locate abnormalities in a cable with a resolution of up to half a meter.
The spatial resolution of a cable fault location method by frequency domain reflectometry was examined experimentally by giving two abnormalities intentionally along a 31.5-m coaxial cable. As a result, two clear signal peaks appear, which can locate the presence of two hot spots perfectly if they are separated by more than 30 cm at a position about 15 m from the cable end with a measuring device. In addition, a clear signal peak with a small shoulder is recognized if the two hot spots are 1 cm away. Although the abnormalities were given in this research by heating the cable using tape heaters, the spatial resolution should be theoretically similar for any type of fault in a cable as long as it changes the characteristic impedance of the cable. (c) 2021 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐