4.7 Article

Application of magnified digital in-line holography (MDIH) to the measurement of the evaporation process of desulfurization wastewater droplets in a high-temperature gas flow

期刊

FUEL
卷 292, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.fuel.2021.120307

关键词

Magnified digital in-line holography; Evaporation; Desulfurization wastewater; Micro-droplet; High temperature

资金

  1. National Science Fund for Distinguished Young Scholars [51825605]

向作者/读者索取更多资源

The study used magnified digital in-line holography to measure the evaporation process of deionized water droplets and desulfurization wastewater droplets, revealing that the evaporation rate of deionized water is approximately twice that of desulfurization wastewater. By investigating three aspects of droplet evaporation, the data presented are valuable for achieving zero discharge of wastewater and optimizing operating conditions.
A magnified digital in-line holography was applied to measure the evaporation process of deionized water droplets and desulfurization wastewater droplets in the temperature range of 298?423 K. A quartz-glass evaporation chamber was designed to conduct experiments. The total length in the measurement zone was 450 mm. The droplets were generated by a piezoelectric jetting device (Microfab Inc., Plano, Texas, USA). The nozzle (MJAT-01-50) consisted of lead zirconate titanate piezoelectric ceramic (PZT) material and a glass capillary with a 50 ?m orifice diameter. The relationships between the evaporation process and operating conditions, such as temperature, the concentration of desulfurization wastewater, added solutes, and velocity of carrier gas, were discussed. The evaporation rates of deionized water at 298 K, 323 K, 373 K, and 423 K were 0.1156 ?m2/ms, 0.3398 m2/ms, 0.5204 m2/ms, 0.6381 ?m2/ms, respectively. The evaporation rates of desulfurization wastewater at 298 K, 323 K, 373 K, and 423 K were 0.05201 ?m2/ms, 0.1673 ?m2/ms, 0.2912 ?m2/ms, 0.3606 ?m2/ ms, respectively. The evaporation rate of deionized water is approximately twice that of desulfurization wastewater. The progress hereby presented enables us to study the evaporation of droplets in three aspects: First, the evaporation process of a monodisperse droplet stream injected into a high-temperature gas flow can be investigated. Second, the equivalent pixel was calculated to be 2.4299 ?m/pixel and the magnification factor was 5.76. Third, factors affecting the evaporation rate of desulfurization wastewater are investigated. The data are valuable for achieving zero discharge of wastewater and optimizing operating conditions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据