4.6 Article

Combined leadless pacemaker and subcutaneous implantable defibrillator therapy: feasibility, safety, and performance

期刊

EUROPACE
卷 18, 期 11, 页码 1740-1747

出版社

OXFORD UNIV PRESS
DOI: 10.1093/europace/euv457

关键词

Pacemaker; Leadless pacing; Subcutaneous ICD; Animal experiments; Human

资金

  1. Boston Scientific Corporation
  2. St Jude Medical
  3. Medtronic
  4. Atricure
  5. NWO/ZonMW VIDI [016.146.310]

向作者/读者索取更多资源

The subcutaneous implantable cardioverter-defibrillator (S-ICD) and leadless pacemaker (LP) are evolving technologies that do not require intracardiac leads. However, interactions between these two devices are unexplored. We investigated the feasibility, safety, and performance of combined LP and S-ICD therapy, considering (i) simultaneous device-programmer communication, (ii) S-ICD rhythm discrimination during LP communication and pacing, and (iii) post-shock LP performance. The study consists of two parts. Animal experiments: Two sheep were implanted with both an S-ICD and LP (Nanostim, SJM), and the objectives above were tested. Human experience: Follow-up of one S-ICD patient with bilateral subclavian occlusion who received an LP and two LP (all Nanostim, SJM) patients (without S-ICD) who received electrical cardioversion (ECV) are presented. Animal experiments : Simultaneous device-programmer communication was successful, but LP-programmer communication telemetry was temporarily lost (2 +/- 2 s) during ventricular fibrillation (VF) induction and 4/54 shocks. Leadless pacemaker communication and pacing did not interfere with S-ICD rhythm discrimination. Additionally, all VF episodes (n = 12/12), including during simultaneous LP pacing, were detected and treated by the S-ICD. Post-shock LP performance was unaltered, and no post-shock device resets or dislodgements were observed (24 S-ICD and 30 external shocks). Human experience : The S-ICD/LP patient showed adequate S-ICD sensing during intrinsic rhythm, nominal, and high-output LP pacing. Two LP patients (without S-ICD) received ECV during follow-up. No impact on performance or LP dislodgements were observed. Combined LP and S-ICD therapy appears feasible in all animal experiments (n = 2) and in one human subject. No interference in sensing and pacing during intrinsic and paced rhythm was noted in both animal and human subjects. However, induced arrhythmia testing was not performed in the patient. Defibrillation therapy did not seem to affect LP function. More data on safety and performance are needed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据