4.7 Article

Can T2-weighted Dixon fat-only images replace T1-weighted images in degenerative disc disease with Modic changes on lumbar spine MRI?

期刊

EUROPEAN RADIOLOGY
卷 31, 期 12, 页码 9380-9389

出版社

SPRINGER
DOI: 10.1007/s00330-021-07946-2

关键词

Low back pain; Intervertebral disc degeneration; Magnetic resonance imaging

向作者/读者索取更多资源

The study demonstrated that an MRI protocol consisting of only sagittal T2-weighted Dixon fat and water images provided good diagnostic performance and interobserver agreement in lumbar degenerative disc disease with Modic changes, suggesting it could be a viable option for a shortened MRI protocol.
Objectives To evaluate the diagnostic performance and interobserver agreement of a magnetic resonance imaging (MRI) protocol that only includes sagittal T2-weighted Dixon fat and water images as an alternative to a standard protocol that includes both sagittal T1-weighted sequence and T2-weighted Dixon water images as reference standard in lumbar degenerative disc disease with Modic changes. Methods From February 2017 to March 2019, 114 patients who underwent lumbar spine MRI for low back pain were included in this retrospective study. All MRI showed Modic changes at least at one vertebral level. Two radiologists read the standard protocol and 1 month later the alternative protocol. All MRI were assessed for Modic changes (types, location, extension) as well as structural changes (endplate defects, facet arthropathy, spinal stenosis, foraminal stenosis, Schmorl nodes, spondylolisthesis, disc bulges, and degeneration). Interobserver agreement was assessed, as well as diagnostic performance using the standard protocol as reference standard. Results Interobserver agreement was moderate to excellent (kappa ranging from 0.51 to 0.92). Diagnostic performance of the alternative protocol was good for detection of any Modic change (sensitivity = 100.00% [95% CI, 99.03-100.00]; specificity = 98.89% [95% CI, 98.02-99.44]), as well as for detection of each Modic subtype and structural variables (sensitivity respectively 100% and ranging from 88.43 to 99.75% ; specificity ranging respectively from 97.62 to 100% and 99.58 to 99.91% ). Conclusions Combined with T2-weighted Dixon water images, T2-weighted Dixon fat images provide good diagnostic performance compared to T1-weighted images in lumbar degenerative disc disease with Modic changes, and could therefore allow for a shortened protocol.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据